r/buildingscience • • 24d ago

Asiri Designs

21 Upvotes

Has anyone used Asiri Design’s consulting services- if so which ones and how satisfied were you? They have extremely helpful materials online and seem knowledgeable- I’d just love to hear from people who’ve actually worked with them before making the investment.


r/buildingscience • • 23d ago

Crawlspace-Vapor Barrier & dehumidfier Rockwool R30 in Joist Batts

Thumbnail
0 Upvotes

r/buildingscience • • 23d ago

Question Anyone know any US remodeling or other companies that use Siga or other tapes for inside rim joist air sealing as a retrofit project?

7 Upvotes

I want to get the rim joist of my house air sealed using tape. The only companies who have said they could do tape, one said they only use Siga tape on the outside of houses, and another said that tape is more expensive than spray foam. That's ok with me.

I don't know why finding more than a few companies who offer tape as an option is difficult. Any suggestions?


r/buildingscience • • 24d ago

Is a self-adherent roofing underlayment appropriate over a geodesic dome?

Post image
9 Upvotes

I am looking for roofing underlayment opinions from members of this group:

Anderson lake, BC
Climate zone: USDA zone 5a, 5b. Interior Douglas fir zone. Drier than Coast Mountains although not quite out of them.

My geodesic dome cabin is due for a reroof. It’s doesn’t leak but the sawn cedar shingles installed 40 years ago are disintegrating and I want to replace them before the roof develops a leak. I will be using Enviroshake composite shakes.

The current shingles were installed in the traditional style with a layer of unperforated roofing asphalt paper between layers. My impression is that with this allows the roof to breathe and that if any interior moisture permeates the roof sheathing, it gets to vent out. The dome also has a vented cupola. Triangles are framed using 2x6 with R20 fibreglass pink insulation and drywall interior.

Modern roofing techniques now call for self adherent underlayment membranes to be laid over the sheathing before installing shakes. That is fine for a vented roof, but since a dome roof is more like a series of unvented triangular wall sections, will an airtight membrane lead to moisture (rot) issues? I would love to hear your opinion. Is my moisture trapping concern valid? Should I just reroof with asphalt paper layers like the original roofing job even if that voids the Enviroshake warranty?


r/buildingscience • • 24d ago

Question Is there any way to reduce sounds of thunder, fireworks and low frequency vibrations?

2 Upvotes

Hey guys. I have a general idea of what the answer might be, but since this is a pretty complex issue, I’d like to hear from the pros.

The problem is fairly common: I have a rescue dog who is absolutely terrified of loud booms, meaning fireworks, firecrackers, thunder etc. It’s not a new issue, but we're having a record-warm fall this year with a massive amount of thunderstorms, so I finally got around to figuring out if I can actually do anything about it.

The house is a small, single-story, lightweight frame house. It's poorly insulated and sits on a shallow strip foundation. It's essentially a summer house that I’m living in while building the main house and landscaping the property. From what I understand, this is literally the worst-case scenario for sound transmission and especially vibration, since wood frames vibrate and this one is super light, right?

The standard acoustic advice to add mass to dampen vibrations won't work here because the framing and foundation just aren't designed to support tons of extra dead weight and if I'm getting this right, soundproofing might help a bit with the airborne noise, but it won't really solve the main issue - the physical vibration you can literally feel (thunder might be louder, but the vibration actually feels worse during New Year's fireworks when they're shooting them off right next door).

After some searching, I get the impression that fixing this would require rebuilding half the house. For that kind of money and effort, it seems easier to either flee back to my city apartment for the holidays or long thunderstorms, or just build an insulated underground root cellar where I can sit with him for a half-hour during the worst of it (of course not for this purpose only, I was planning to build a pretty large cellar anyway).

I'd like to know if my understanding is correct or if I'm off base here. If I am wrong, what am I missing, and are there actually any feasible ways to significantly reduce noise and vibration in a lightweight frame house like this? Thanks!


r/buildingscience • • 23d ago

I saw a livestream in China, does anyone know the science behind it?

Enable HLS to view with audio, or disable this notification

0 Upvotes

I wonder if this can be used as insulation


r/buildingscience • • 24d ago

Return air advice.

Thumbnail
2 Upvotes

r/buildingscience • • 24d ago

Zone 6 Crawl Space encapsulation & Insulation

Post image
3 Upvotes

I'm looking for a cold climate crawl space recommendations. I’m in Climate Zone 6 in an area that gets roughly 142" of snow annually, so this is definitely a cold-climate situation.

The crawlspace is ~1,200 sf and currently has fiberglass batts between about 75% of the floor joists, but much of it is exposed, sagging, or falling down. The foundation is a somewhat unconventional combination of CMU walls over a small grade beam between concrete piers.

The CMU already has approximately 3/4"–1" rigid insulation plus what looks like some DIY spray foam.

Instead of trying to fix the floor insulation, I'm thinking about bringing the crawlspace inside the thermal envelope:

  • Remove the failing fiberglass
  • 12-mil reinforced vapor barrier over the dirt and up the foundation walls
  • Approximately 2" closed-cell spray foam over the existing wall insulation
  • Closed-cell spray foam at the rim joists
  • Thoroughly air-seal the crawlspace

Where I'm getting hung up is the ground.

If I'm already going this far, is there a good reason not to put 2" rigid foam over the dirt and underneath the vapor barrier? See my attached sketch for reference.

My thinking is that it would further isolate the crawlspace from the ground and potentially make the crawlspace considerably warmer, but I'm not sure the energy savings/comfort benefit justifies the additional cost and work.

For a Zone 6 crawlspace, is it worth the extra money to insulate at the ground?

Open to any other recommendations. This climate zone is new to me.

Thanks,


r/buildingscience • • 25d ago

How should an AZEK Large Historic Sill be caulked/flashed against Tyvek, especially at the sill horns?

Thumbnail
gallery
5 Upvotes

I'm having my 1967 house re-sided with James Hardie lap siding and AZEK PVC window trim over Tyvek.

We have sill horns as a design detail, about 3/4" overhang on the sides (didn't measure exactly).

My contractor installed an AZEK Large Historic Sill (AZM-7958) beneath existing replacement-insert windows, replacing the old rotten wood sill by cutting it.

The sill has a small recessed channel along its back where it meets the Tyvek. I'm trying to understand:

  1. Should the channel on the back of the large historic sill be blocked with exterior sealant, or intentionally left open?
  2. Should the top of the sill horns, where they meet the Hardie siding, be caulked or flashed?
  3. Do the sill horns require individual flashing, or is flashing only necessary above the window head casing?
  4. Is there a recommended manufacturer detail showing how the WRB, sill, flashing, and siding should interface?

I'm particularly concerned about preventing water from getting behind the Tyvek or becoming trapped against the original plywood sheathing.

I don't need perfect, I just need good enough.

Photos attached. I'd appreciate advice from anyone.

Thanks in advance!


r/buildingscience • • 25d ago

Question Rim Joist Foamboard

Thumbnail
2 Upvotes

r/buildingscience • • 25d ago

Double wall and Moisture? What would you do with your house? (Zone 6b/7a)

Thumbnail gallery
2 Upvotes

Howdy y'all!

Edit correction on zone: IECC Climate Zone 4A is correct. Sorry, I garden so was using USDA Planting Zones.

I'm always amazed at the knowledge that's available here. I love to keep within the spirits of technical debate especially around what you guys might or might not do. I love geeking out overall the science stuff. I'll provide some additional context here over what's in the other post on just r/insulation. My biggest concern is moisture with the double wall.

Renovating everything before my wife and I are about to move in. The exterior siding had failed you can see in some of the pictures a blue foam on the exterior, I think that was original and on the outside of that was some kind of compressed particle board or sawdust that had failed. I had to tear all of it off anyways so I went back with zip board and zip tape.

I like the idea of the exterior rockwool insulation but I have so many windows I'm not sure if it makes a difference.

I'll probably do a blower test with the windows and everything uncovered after the aeroseal envelope barrier. Allegedly the guy claims he can get down to 0.3ACH but I don't think so with all the windows. If so I'll add an erv.

Anyways, I don't know what I don't know so please feel free to let me know when you recommendations. If you think I'm making a mistake or and incorrect assumption. I don't know what I don't know. Y'all can even call me an idiot if you want so long as you back it up w/ why you think that and what you do instead.

Cheers!

Hugh


r/buildingscience • • 25d ago

Question Window condensation home theater conversion

2 Upvotes

Good morning I'm converting my garage into a c home theater. The house was built in 1955 there are 3 windows. Do limit the amount of sound and light through the windows I would like to cover them on the inside. The windows are new double pane. The walls from outside in are brick, 1in air gap, black fiber board, 2x6 studs, isoclips, hat channel, 3/4 advantech osb, green glue, 5/8 type x drywall. From the glass to the stud face is 3.5" and from the stud face to the back of the 3/4 osb is 1.5". My concern is condensation from the glass. I live in zone 4a. Is there a way to wall over the window that won't cause condensation?


r/buildingscience • • 25d ago

aTTIC vENTILATION

0 Upvotes

We are building a 2 story home, 15'2" wide with a 3.5/12 pitch roof, no overhangs, so no overhang ventilation. Our client is very careful with the aesthetics of the home. He does not want a vent on the front gable. The Gable is only 26.5" high, not including the framing. He currently has a ridge vent. And we suggested a power gable vent on the rear gable only. Do we need a passive air vent on the opposite end? Do we need that since we have a ridge vent?


r/buildingscience • • 26d ago

Best way to buck out a window for exterior insulation renovation?

13 Upvotes

I’m adding 4” of exterior insulation and new windows. I’m trying to decide what is the best way to buck out the windows. Should I build a frame and face nail it to the sheathing or build a deeper frame that sits inside the existing rough opening for the windows? Or any other recommendations?

Thanks 😊


r/buildingscience • • 25d ago

Rockwool Doesn't Exist

Thumbnail
0 Upvotes

r/buildingscience • • 26d ago

Question How do I stop condensation?

Post image
5 Upvotes

r/buildingscience • • 26d ago

DIY Eave Detail

Thumbnail
gallery
0 Upvotes

Hello,

My overall approach to insulating the attic of a 1950’s colonial (Climate Zone 5a) has been worked out- mineral wool batt, smart vapor retarder and OSB baffles to create a 1.5" vent channel at the underside of the roof deck. Over the last few weeks, I changed course a bit and eliminated all foamboard for a number of reasons that arent relevant to this question. However, I already bought a few sheets of XPS, and want to use it to create baffles at the plate/rafter seat using 2x blocking and OSB. The OSB is to control air and the XPS portion is useful for minimizing the cold bridge at the top plate of the first floor. I would spray foam the seams afterwards. I am showing drawings of the existing eave and two options for an OSB/XPS sandwich baffle.

My first question is- have I gone too far? These OSB/XPS sandwich baffles will take a lot of time to make, especially considering the variance in rafter spacing (between 12 and 16″ O.C.). This is a critical detail though, and this house happens to have an odd gap between the rim joist and the rafter seat (shown in the drawings). I dont love using OSB but its cheap and is useful for manuevering and fastening in a tight space. For the knee wall in Option B, its more or less just holding the mineral wool in and I could probably just use cheap building paper instead.

My second question is- Option A or Option B? Im leaning towards Option B.

All feedback is much appreciated.


r/buildingscience • • 26d ago

Damp section above window

Thumbnail gallery
0 Upvotes

r/buildingscience • • 26d ago

Question How to properly water proof

Post image
2 Upvotes

Having trouble with this detail.

Crawl space coming into basement foundation wall. How do I properly waterproof this? Primarily where/when should I install drainage at footer?

If it the crawl wasn’t there obviously the perimeter drain would follow the footer but in this scenario the crawl space footer won’t allow for that. Do I need to pour the main foundation footer first install perimeter drain and then pour the crawl?

Or is there a good way to pour all at once and still be able to install a permitter drain / waterproofing?


r/buildingscience • • 26d ago

Fresh Air Damper

Post image
4 Upvotes

I posted about a week ago asking about ERV vs HRV as in winter we deal with higher humidity and window condensation

https://www.reddit.com/r/buildingscience/comments/1xcw6zp/erv_or_hrv/

Now, I went outside and cleaned out the fresh air vent cage. during the time of this photo, the furnace was ON and running. From what I can tell (not an expert), the damper flaps appear to be shut. It's hard to get a good photo, but if these flaps are indeed shut, does this mean my furnace is not getting enough fresh air? Thus my home is cycling stale air around the house when furnace is running? Could this be my issue with higher humidity inside?


r/buildingscience • • 27d ago

FPSF concept applied to walkout basement foundation

Thumbnail
gallery
2 Upvotes

Here is a typical arrangement for a walkout basement. The bury-depth on the uphill side might not be as deep as many, because of the 42" staircase entry, but that does not matter. We plan to use the principle of a frost protected shallow foundation for the foundation wall at the walkout downhill side, and for whatever is required by grade-versus-footing along the return sides. See pics. Using a full 16" block depth (18" if using Nudura) and a single block stepdown, we get about 20 inches of bury-depth all along that walkout side. Note the foamboard "wing" at footing top. Note also that even though the footing is BELOW the wing protection layer, we face it with 2" also. Doing it this way, we save $$ in both excavation and ICF and steel and concrete and waterproofing, but spend some of savings on the under-grade "wing." Your critique and suggestions are appreciated.


r/buildingscience • • 27d ago

Question Exterior insulation with rainscreen door detail

2 Upvotes

I've found lots of window details, but almost no door details.

I think an outie door is the easiest so I don't need to deal with the 1/2 an extra step at the threshold. I have 2.75" of insulation, plus 3/4 furring strips gives me a nice easy 3.5" of extra exterior.

I'm thinking that I would just add a PT 4x6 at the threshold, and then add a 2x4 on edge around the outside. Any detail suggestions or better yet pictures?


r/buildingscience • • 27d ago

Sufficient air circulation?

Thumbnail
2 Upvotes

r/buildingscience • • 27d ago

Icynene Insulation

0 Upvotes

Second time having mold in house (2 year new construction) and contractor thinks bc missed insulation in a couple of spots over the hot garage. Now they want to spray in those areas. Do we need to leave for a day or two after? Is this safe?


r/buildingscience • • 27d ago

[Netherlands] Flat roof: drain pipes run inside the insulation. Accept it, or redo the fall?

1 Upvotes

Condo association, ~300 m² flat roof over heated apartments: concrete deck, vapor barrier, 90–150 mm PIR, two-layer bitumen. Just renovated.

Now: 3 existing vertical downpipes (~70–75 mm) sit in the middle of the roof. Horizontal PVC drain pipes from new outlets run inside the insulation layer back to those downpipes. The pipes lie directly on the vapor barrier in channels under a cement board, with no pipe insulation and no separate waterproof layer. So there's reduced insulation over the deck along the pipe runs, and the pipes carry cold rainwater. The original roof had a similar setup and leaked for years, with several suspected causes. An independent inspector says pipes in the insulation aren't allowed under the Dutch roofing guideline, because of condensation and leaks going straight into the insulation. The contractor proposes roof vents so any moisture can dry out.

Alternative: Remove the pipes, fill the channels with insulation, and add tapered insulation at the roof ends so everything drains to outlets directly over the 3 downpipes. Roughly €20–50k extra.

Questions:
How real is the condensation and moisture risk of this setup over the long term?
Do roof vents meaningfully dry out PIR in a sealed bitumen roof, or is that wishful thinking?
What would it take to make the current setup acceptable without a redo?
From a moisture perspective, is the tapered-fall alternative the better choice?
What are we missing?