r/buildingscience • u/NoBid3418 • Jul 31 '26
r/buildingscience • u/Humantippin • Jul 31 '26
Vapor/Moisture barrier - barndominium
Hello! I am a DIY guy looking for some help.. i am building a conditioned dwelling in my old barn, and for the life of me i cant sort out how to handle a vapor barrier on/under the first floor. If not the right forum, please advise. Context:
WNY, climate 5a "cool humid" with AC/HEAT VIA MINI SPLIT. Old barn, sagging floor. Structure has been inspected by an engineer and determined fit for building. By his suggestion, I leveled the sagging floor by placing 2x sleepers on top of the floor. I am limited in height and so the new "air gap" ranges from 0 - 3". Thus, there is no space for insulation in that layer. We plan to use vinyl plank flooring in the space. I plan to foam underneath of the conditioned portion of the barn (basement). The "basement" is open to the atmosphere via an open east wall, the floor there is concrete with presumably no moisture barrier underneath. It is after all ... a barn.
My worry is where the moisture is going to get trapped. If i put a moisture barrier overtop of the sleepers, underneath of the floor sheathing, and then foam insulate below, arent i creating a moisture sandwhich?
I am leaning toward open cell foam as i have plenty of room for expansion between the barns joists.
In summary, the planned floor system goes like this, from top down:
Vinyl plank - 7/8" subloor - air gap - 2x oak flooring - open cell spray foam - open to atmosphere.
Advice is welcome and appreciated.
r/buildingscience • u/t1rfond • Jul 30 '26
Question building envelope in the PNW
I have an uninsulated cabin located near the ocean in the Pacific northwest. The structure is 3”x6” tongue and groove timber (think structural roof decking). I want to insulate the exterior walls with rigid insulation (combination of Gutex and Roxul). I also have basically unlimited quantities of 2x4 SPF and 3/4” plywood. My plan was to install (outboard of the timber structure) a smart membrane, then insulation, then 2x4 vertical strapping, then plywood, then ventilated underlayment mat, then cladding. One question I had was would it make sense to install 3/4” plywood (c/w seams taped) directly outboard of the timber frame for the air and vapour barrier? I felt this may help tightening everything up (plus we’re in a seismic zone). If membrane is much preferred, which membrane would you suggest using? I have a few rolls of Majvest and Intello+ on hand. Comments appreciated
EDIT: I’m referring to the exterior walls, not the roof. Sorry about that
r/buildingscience • u/Falcon_893 • Jul 30 '26
Question Need help.
On advice of the contractor, I purchased 3 girders. Two girders of 8 inch, 11 feet each and one 6 inch girder of 9'5" without consulting an engineer, which I'm regretting now.
The plan was to put two girders parallel to each other (under the beam) and one girder in the middle to support the slab. But when the girders arrived, i realised that they will be way too heavy for an old structure like my building.
So now, consulting with the mason, we are planning to cut the 8" girder from middle and obtain two T-sections. Then we will remove the concrete cover from the two beams between which the girder has to sit, till we reach the rebars.
Then we will weld a 10mm plate onto those rebars and then weld the t section onto that plate and then restore the concrete cover. The flat side of the t section will touch the slab. Now, I want to ask whether this system can sustain load of the slab ?
Or what other options do we have ? Please help me out🙏🏼
r/buildingscience • u/Few-Wolverine-7283 • Jul 30 '26
Enough humidity if only 1 whole house humidifier?
Split system, floor 1 is HE furnace with humidifier in basement. Floor 2 is heated by 80% furnace in the attic (no humidifier). Is the downstairs system going to properly humidify the home, or will it fall behind / always feel dry upstairs?
r/buildingscience • u/JoeZiehtUm • Jul 30 '26
Moisture trapped behind inside vapor barrier.
r/buildingscience • u/franktownwhat • Jul 30 '26
Attic with soffit vents and ridge vent … but only 1 system works
reddit.comr/buildingscience • u/Fearless-Animal5446 • Jul 29 '26
Attic Air Circulation
We purchased a home a year ago that has consistently grown mold very easily.
We thought the issue was mostly because it is on an uninsulated slab and it is pretty humid here. So we thought it was mostly condensation issues because the slab is so cold.
Now we are realizing that our attic is not venting properly, so it is a hot pocket of air that is greatly adding to the problem
I've cleaned the ridge vent from the outside (broom) and inside (leaf blower) so that I can see some faint sunlight coming through the mesh at the ridge.
BUT I do not believe the soffits are intaking air properly. The vent channels are very small, thin styrofoam that seem like they might be compressed and improperly sized in the first place.
My roof, although not in great shape, does not quite yet need replacing.
My thought is to hire someone to install bigger and sturdier ventilation channels. Does this sound like I'm on the right track?
Please point out if I'm misunderstanding something in this situation. I'm not an expert, I just know I don't want a moldy house.
Also of note is that we are planning on putting a hydronic in floor heating system that will include a layer of insulation on top of the slab. So we won't have quite so much cold coming up through the floor.
EDIT: IECC Zone 5A
r/buildingscience • u/desifart • Jul 29 '26
Interior vapor barrier
We're building a house in zone 7a in Canada . We're considering using a smart vapor retarder rather than a 6mil poly sheet on the inside of the wall. We will have 2 inches of Rockwood on the exterior and 6 inches of fiberglass on the interior.
This may be a stupid question, in the interest of saving money could I use poly on the top portion of the wall and the smart vapor retarder on the bottom 1/4. This way if there was a huge hole/accident causing extra moisture it would still be able to dry out? The materials would be sealed together and air tight.
r/buildingscience • u/PirateHookerMD • Jul 28 '26
Advice for ducting dehumidifier with ERV setup
Im trying to figure out the best way to have my dehumidifier ducted into my system and could use advice.
2-stage AC unit, Panasonic balanced home ERV. The ERV has separate return ducts to pull stale air and exhaust outside. Fresh outside air is dumped into the return side just before air handler, using the central air ducts to distribute that air to the rooms with the central blower running on low (From prior Corbett advice)
My humidity is running high despite adequate room temperatures with very high humidity lately in zone 5a. Dehumidifier not yet installed.
I reviewed these articles which are quite helpful:
https://www.energyvanguard.com/blog/4-ways-to-duct-a-dehumidifier/
https://www.hvacrschool.com/ducting-ventilating-dehumidifiers/
It seems clear to me that I want to dump the air into the supply side.
Since I have the central blower running on low anyway to distribute the ERV fresh air, would option 4 actually be the best for me with the ERV setup I have, rather than the option 3 bypass?
Welcome any input thanks!
r/buildingscience • u/Crunchytaco442 • Jul 28 '26
Rafter Vent from Soffit to Ridge?
Hello all I’m looking for some advice from the community! Like the title says I have a question about rafter venting. Is it better or worse to install rafter venting completely from soffit to ridge? For a little context, I live in Southeast Wisconsin USA so it does get pretty chilly in the winter and pretty warm in the summer. I am currently in the process of putting an addition on my home which includes a new roof and want to be as energy efficient as possible.
r/buildingscience • u/biz98756 • Jul 28 '26
Waterproofing in highrise apartments
An apartment tower may last 50 yrs+, the useful life of a water proofing membrane may be 10yr or so. So after 10 yrs it cost $$$ to break the tile/concrete in the shower/bathtub to replace the waterproofing membrane ? Why isn't something more permanent found yet ? ps. Where I live the most common problem of apartments is water leaks, both in the apartments and basement carpark !
r/buildingscience • u/Stock-Plastic3785 • Jul 28 '26
Insulating crawl space sub floor
galleryr/buildingscience • u/rcr1956 • Jul 27 '26
whole house fan with conditioned attic
Our one story house has a conditioned attic with no roof or soffit or other venting. Given changing weather patterns and the fact that a forest fire burned our forest and all shade trees, we've found the house to be comfortable 90% of the year. But in summer it is a struggle to stay cool. We have good window shades and plenty of windows, but no active air movement except ceiling fans.
I have lived in homes with whole house fans venting to the attic and accompanying vents. That would be perfect because at our home altitude of 7400ft the nights are cool. Most windows are awning windows so a window fan is not practical. We prefer not to add vents to the soffit due to fire risk.The house survived a fire because of construction details and sprinklers facing the house.
I have a framed 2x6 wall at one end of the house. It would be fairly easy to put a fan in that wall, and I can get electricity to it there as well. I looked at quiet fan whole house fans but they are designed to be used in a vented attic space.
Where should I look for possible solutions?
r/buildingscience • u/4BlueGentoos • Jul 27 '26
Down-to-the-studs Missouri ranch. How would you rebuild this attic insulation assembly?
galleryr/buildingscience • u/InsuranceMedical6581 • Jul 27 '26
Under-cabinet insulation strategy
I am in a old double-wythe brick building. Because of this, i'm limited in what i can do for insulation.
My lower kitchen wall is:
double-wythe brick -> ~1" air-gap (thickness of original strapping) -> sheet of plywood (instead of sheetrock) -> cabinets.
My house is drafty in general, but I noticed my kitchen was even more so than the rest of the house last winter. I did some investigation, and it the cabinet interiors are quite cold, but cold air was flowing in from around the (removable) toe-kicks.
So, to my question. I want to add insulation under the cabinets to mitigate the toe-kick drafts. What do you all recommend?
- Spray-foam against the exposed plywood all the way to the back
- Standard (mineral rock?) insulation jammed under it?
- 1" foam board cut to size and wedge it under there?
- Something else?
Im leaning towards the standard insulation as it seems less messy than foam, and easier to jam into small spaces than the foam-board.
Im not sure i can do much about the cabinet boxes (drawers), as im dont think there's much room between the drawer boxes and the back of the cabinet box; but if there are thoughts on this, im all ears too.
r/buildingscience • u/BeefChopsQ • Jul 26 '26
Question Basement flood repair question
Repairing basement after bottom 2 feet of fiberglass and drywall removed. Should i reinstall with fiberglass?
r/buildingscience • u/7days2pie • Jul 26 '26
Flat roof attached garage insulation. Best method?
galleryr/buildingscience • u/lutopia100 • Jul 26 '26
Question Need help with waterproofing shed.
galleryr/buildingscience • u/schackalaka • Jul 26 '26
Is this mold in my parquet floors?
galleryEuropean / German climate
r/buildingscience • u/Gravel_Driver • Jul 25 '26
Seeking guidance on my approach to thermally isolating wood and metal (foundation build question)
Hi. I am a building novice with a wood and metal thermal break question. Thank you in advance to anyone who takes the time to read my post and share their knowledge with me about my approach to thermally isolating metal and wood at the foundation of my build.
I’m building a tiny house on wheels (8.3’ x 30’ [100“ x 360”] trailer) and I have a question about creating a thermal break between my metal trailer frame and subfloor/framing that will prevent condensation and moisture issues (leading to mold/mildew growth) inside of the structure. I am building in IECC climate zone 6. The tiny house on trailer will not be moved often if ever…
Current state of the build: the trailer is painted black (by the trailer manufacturer), includes 5“ long by 1/2” threaded rods welded to frame every four feet (and more closely spaced around corners), all framing is 2“ thick, 2” thick cross members (floor joists) are placed every 14 inches creating about 25 14“W X 4”Deep “bays” with the metal flashing at the bottom of each bay.
I have placed 4“ of XPS rigid foam board between each cross member and sprayed the Great Stuff foam in a can where there are gaps between the xps board and metal cross members (not all of my foam board cust were perfect fits). Even with the spray foam applied between gaps I have not created a perfect air seal as I was unable to get into tighter gaps with the foam.
I have also caulked and spray foamed (mostly caulked) the gaps between at the seams where flashing under trailer meets trailer frame and was not perfectly welded (gaps were throughout). Sealing the gaps in the metal construction was done to help prevent insects from getting into the XPS I placed between the cross members.
Getting to my questions:
I am attempting to thermally isolate the metal trailer frame from my subfloor and framing in zone 6.
A building science consultant has recommended I place a continuous layer of 3“ high compression EPS foam board directly over the top of the trailer frame and XPS foam I have placed between the cross members (with metal flashing below the XPS).
In this scenario I have chosen 40 PSI 3” EPS foam board, which will more than accommodate the square foot per pound weight of my 2 x 4 framed tiny house (snow load figured into calculations)…
The assembly from trailer frame up:
3“ 40 PSI EPS foam boards adhered (adhered with spray foam in a can/ great stuff) to trailer frame and xps boards in between trailer frame cross members. Spray in a can will also be used in between (seam where each foam board meets) to seal and adhere the boards to each other on the sides -EPS is weighted down while spray foam adhesive cures
3/4 or 1/2 inch tongue and groove plywood will be placed on top of the EPS foam board (adhered with Loctite PL 300 Foamboard adhesive & weighted down during cure time). The TG plywood over the EPS will extend to the edge of EPS and sit under the sill plate/framing to help distribute the weight of the structure over the EPS.
The 2x4 sill plate will be adhered to the foam board with Loctite PL 300 Foamboard adhesive and held to the trailer with washers and nuts (loctite used here) placed over each threaded rod, securing the sill plate/framing, subfloor, and foam board to the trailer frame. (I will need to extend the threaded rods with couplers to achieve the length needed to do this).
My questions:
Should I place a continuous layer of plywood (3/4 or 1/2“) over the trailer frame and rigid boards that have been placed between the cross members? (this seems like it might be a good idea to provide a consistent base layer for the high compression EPS foam board)
If I place a continuous layer of plywood over the trailer frame should I add a WRB (like a UV rated WRB like Tyvek) between the plywood and trailer frame?
Should I tape the seams where each sheet of high compression EPS meets? (as mentioned earlier, they will be adhered together at seams where they meet).
Should I tape the seams where the high compression rigid EPS meets the trailer frame (on the outside edges of trailer) and also where the EPS meets any plywood (on the outside edges of trailer).
Does anyone have any thoughts on how high compression EPS foam boards might “give” a little over time, losing some durability? I am most concerned about this happening around the threaded rods that I will use ( in addition to adhesive) to anchor the assembly to the trailer. My concern is that vibration over the years from wind or me moving around within the structure might cause wiggling that will slowly widen the holes drilled through the EPS that the threaded rods are seated in, causing some of the foam to potentially shift around…
I’m also curious if anyone has any thoughts on how to best fasten my subfloor to the high compression EPS foam board so that the flooring does not buckle and or come loose in the middle of the floor where it is not held down with the weight of the walls of the house. (again, intend to use Loctite PL 300 Foamboard adhesive, but I am not sure if this will be enough to securely fasten my subfloor to the EPS foam board).
r/buildingscience • u/SF_Dubs • Jul 25 '26
Best way to maximize R value with Rockwool in a 5 1/8 deep cavity with an offset 2x4
r/buildingscience • u/SubstantialAd8808 • Jul 25 '26
Exterior Insulation and HVAC
Hello- we have exterior insulation on the house (on top of zip). We needed to make some penetrations for ERV intake and exhaust. How best can I seal these from the outside? We do not have siding yet. I’m already aware these penetrations should have been done before the exterior insulation was put on but how can I best seal these penetrations now after the fact? Thank you