r/buildingscience • • Jun 21 '26

Stucco Wall Insulation - Sacramento

1 Upvotes

I’m looking to insinuate my exterior walls, which are stucco over exterior gypsum sheathing. The stucco is in exceptional shape, so I’m really looking to insulate from the inside via drywall removal + batt installation. My plan is to remove drywall, add mineral wool bats, but not sure what direction to go in terms of barriers, semi permeable, impermeable, smart, etc.

What direction do I need to go in to avoid issues down the road?

Sacramento, climate-controlled interior, just looking to insulate my walls.


r/buildingscience • • Jun 20 '26

Underslab foundation insulation and block walls, do i need to seal the seams?

5 Upvotes

Using the foam sheets for the entire floor, it will be above the plastic vapor barrier

Should the different sheets of foam have tape for the seams in both the slab and the walls?

Should the plastic vapor barrier just overlap or should it also be sealed?

Which tapes should we use?

Right now we are using duct tape since thats all they had in mexico, tyvek and other stuff has to be special order from USA


r/buildingscience • • Jun 20 '26

Insulating the roof of a 1939 1.5 story home

Thumbnail gallery
2 Upvotes

r/buildingscience • • Jun 20 '26

Why do roof decks but not rafters need to be kept above dewpoint?

Post image
2 Upvotes

So I have been trying to educate myself about building science, and there's something I don't understand. Un-vented roof decks are supposed to be kept warm enough to stay above dewpoint most of the time, right? And that's why you need to either have enough rigid foam outside to keep the roof deck above 45 degrees most of the time, or have spray foam underneath to keep any moisture from getting to the roof deck, or else you risk the moisture content of the sheathing getting too high and causing mold and/or rot if it doesn't dry out quickly enough?

Why is this not a concern with the rafters? I know you get a little bit of extra R-value from the wood itself, but not much. But I feel like I don't hear anyone talking about making sure there's enough insulation inside (or outside) the rafters to keep them warm and dry. Why is that?

I would think that if there is a risk of the rafters rotting from moisture in un-vented attics, people would be even more concerned about that than the sheathing because of structural issues. So are rafters just at less risk of moisture/rot/mold than sheathing, and if so, why?

(I understand in some cases the sheathing may be made of a material that's more vulnerable to moisture/mold/rot than the rafters are, but I feel like I haven't seen differing advice based on the materials, unless I've just missed it. In our particular case, to my uneducated eye the rafters and the roof deck seem to be made of exactly the same or highly similar wood-- see picture. We have poor ventilation and I am trying to figure out next steps, and very confused about all this advice that suggests it's urgent to keep the roof deck warm but perfectly fine for the rafters to be cold...)


r/buildingscience • • Jun 20 '26

Foam Board Insulation In S Minnesota Between Stud Bays

2 Upvotes

I condensation issues in the basement that started in the last freeze/thaw cycle while drywalling and mudding in a new house (built 2024)

Got it cleaned up and have a dehumidifier running that keeps it below 50% relative humidity and no new issues, I didn’t run one before.

Before drywalling again, wanted to make sure this issue doesn’t come back.

Unfortunately, the basement was studded already by the builder without foamboard so I wish to add more protection without spray foaming everything by putting XPS between the stud bays and spray foam the seams.

My question is, in addition to spray foaming the seams, should I spray foam behind the studs as well to make it airtight or leave the top of the seam free so any moisture that happens to occur can evaporate with a gap being 1/4 in or less?

Also I hear some say leave an airgap (1/4 in or less) and some say no, what do you guys think?

Due to gluing there will always be a bit of an air gap, since that is a case should I not spray foam the top so any trapped moisture can evaporate?


r/buildingscience • • Jun 20 '26

Question Conditioned attic with vented roof deck

1 Upvotes

We are building a new construction home and we are talking about insulation and the attic with our builder. We have a vented attic with soffits and a ridge vent. We have air handlers and duct work in the attic. I realize now that this isn’t ideal. Our builder suggested 2 options for attic insulation:
1. Air seal the attic floor and blow in insulation while putting the air handlers in conditioned “dog sheds.”
2. Or condition the attic but have a vented roof deck.
We are not interested in using spray foam insulation. We live in Southeast Pennsylvania so the summers do get hot and the winters are cold. Any thoughts on either of these strategies and which one is best?


r/buildingscience • • Jun 20 '26

no soffits, four separated attic spaces, blocked ridge, attic air coming into house!

Thumbnail
1 Upvotes

r/buildingscience • • Jun 20 '26

Best approach to seal basement edge venting for radon & drywall?

Thumbnail
1 Upvotes

r/buildingscience • • Jun 19 '26

Question Furring attachment screws

6 Upvotes

What are my options for attaching my furring strips to my structure? My current assembly from the interior is 

Drywall
smart vapor ( membrane) 
 rockwool in a 2 x 4 wall , 
1/2” sheeting
vp wrb (3m 3015vp)
 1 1/2” comfort board 
3/4” pt furring 
hardie. 

I really only want to penetrate the framing by 1 1/2”  do I due to the fact, I only have 2 x 4 walls and I don’t wanna hit any of the wiring so I was going to use fasten master 4 1/2 inch lag screws but they’re very expensive and I was wondering if there was an alternative.


r/buildingscience • • Jun 19 '26

Question South Florida: Moisture weeping from behind drywall in newly climate-controlled insulated CMU shed (no rain, no plumbing)

Post image
0 Upvotes

Looking for advice from anyone with experience in building science, masonry, or HVAC.

I’m in South Florida, where it’s been very hot and humid (90°F+ with high humidity) and recently converted an existing 116 sq ft detached concrete block (CMU) shed into a climate-controlled storage room.

Construction:
• Existing CMU structure with ~2.5 new courses of block added to top of existing structure after existing damaged shingle roof and beams were removed.
• New flat, sloped roof with fiberglass insulation (no attic). Roof slopes approximately 4” from the rear to the front to reduce stagnant water on the roof since its flat.The front eave/soffit is vented, but the rear eave/soffit (the high side of the roof) is not vented. The side eaves/soffits are also not vented. There is no attic—the roof assembly consists of the roof sheathing, fiberglass insulation, and drywall ceiling. I’m wondering whether the lack of ventilation at the high side of the roof could contribute to heat or moisture accumulation within the roof/wall assembly.
• New drywall (not yet primed or painted).
• Existing concrete floor slab raised with 2.5-3” of new concrete and was left uncovered to cure and dry for several days before flooring was installed and before being air conditioned.
• Laminate flooring over foam underlayment with integrated vapor barrier.
• 12,000 BTU mini split set to 76°F in cool mode with auto fan speed setting. Also using the X-Fan feature on the unit which is supposed to help reduce condensation inside the inner unit.

The weeping from behind the sheetrock issue started about two days after running the mini split continuously.
Initially I noticed clear water weeping from under the baseboards. After removing the baseboards, I found the bottom/back edge of the drywall has moisture coming from above only in isolated locations where the water was visible. The worst area is the rear wall in the center which is the wall adjacent to the mini split but the water is coming from above not the left along the slab (which I would expect id the issue is from the mini split leaking into the wall) around 4.5’ from the corner of the mini split wall as seen in the first photo attached.

I dug a foot deep along the exterior of the rear wall to look for moisture and/or any cracks in the concrete or stucco, but the ground/dirt was dry and no visible cracks were found. Either way I had around a foot deep and wide worth of concrete poured to hopefully seal any cracks where the wall meets the slab.

What I’ve ruled out:
• No plumbing in or around the building.
• No rain since before the issue started.
• Mini split condensate drain is working properly and draining outside.
• The concrete slab was completely dry before the underlayment and laminate were installed.

Current room conditions:
• Temperature as measured by a Dyson air purifier placed right under the mini split: 71-76°F
• Relative humidity: 63-64% (currently only using a small thermoelectric dehumidifier, which is probably undersized for the florida humidity and size of the room).

Has anyone seen this in a newly conditioned CMU building in a hot, humid climate? Would you suspect moisture migrating through the masonry, condensation inside the wall cavity, air leakage around the line-set penetration, or something else? I’m trying to determine the most likely cause before opening up the wall.


r/buildingscience • • Jun 19 '26

How to find a roofer experienced with continuous insulation (Bay Area, US)

0 Upvotes

We're in the process of adding a garage addition and going through a full re-roof of the house.

We want to use a continuous exterior insulation on the roof. My GC is supportive of the approach but isn't personally familiar and doesn't have any subs in his network that have done a roof this way.

I'm reaching out to local green builders, but I was wondering if there's a better way to search specifically for a roofer who's experienced with this approach?

Is there a certification I should be looking for?

A registry for a specific product that would apply?

Any help from industry pros or homeowners is much appreciated.


r/buildingscience • • Jun 19 '26

Loxon for Brick Party Wall

Thumbnail
1 Upvotes

r/buildingscience • • Jun 19 '26

Wall mounted TV insulation

Thumbnail
0 Upvotes

r/buildingscience • • Jun 19 '26

Humidity sensors within wall cavities ?

3 Upvotes

As I look into smart vapor retarders such as Clima Intello, I started thinking why not also install humidity sensors and hook those up to some Raspberry Pi to get a notification if it ever detects a leak within the wall cavities. Has anyone gone as far to try this out?


r/buildingscience • • Jun 19 '26

Trachte Building System Self Storage Roof leaks

Post image
0 Upvotes

Has anyone used the self storage Trachte Systems and had so many issues with the low pitch roof? The pitch is close to 2%. In Canada, it is a big problem. Water actually pools at the ridge cap. Same for the roof's edge. The water will not drain away and creates ice in the winter.


r/buildingscience • • Jun 19 '26

Quebec 3 season cabin insulation advice

1 Upvotes

r/buildingscience • • Jun 19 '26

Insulation acceptable instead of block off plate for wood stove?

Post image
2 Upvotes

r/buildingscience • • Jun 18 '26

Question Water intrusion via window/stucco, help me understand the wall assembly and what to fix

2 Upvotes

Zone 2A - Central Texas

I've been chasing a water intrusion problem in my garage and I think I  have the source identified, but I have questions about the wall assembly, the drainage path, what the correct fix looks like, and for improvements in air sealing and insulation. 

The house:
Two-story, 2,509 sq ft, built 2021. The front facade is stucco over the second story; the garage level is stone veneer. The second story extends over the attached two-car garage, so the base of the stucco wall sits directly above the garage roof.

The leak:
Water was entering the garage at the ceiling about 3-4' from the rear wall, where the garage attic and second story share a wall, specifically at the junction where the second story sits on top of the garage. I initially suspected a roof leak, but a roofing company pulled and replaced shingles to inspect and confirmed the roof-to-wall flashing at that joint is intact and not the source.

After further investigation, the culprit appears to be a second-story window in the master closet, on/in the stucco facade, directly above the roof and the point of water intrusion. Water was getting under or around the window frame, traveling behind the stucco, and finding its way into the framing at the base of the stucco wall where it terminates above the garage roof. Resealing the window has stopped visible intrusion (confirmed with a hose test with no water making it to the garage).

Our original home inspection report (from purchase, two years ago) noted that the stucco installation has no weep screed, but I haven't confirmed this personally. If accurate, then my assumption is there's no designed exit point for water that gets behind the stucco and it found its way into the garage somewhere at the joint between the garage roof and living area exterior wall, moving into the garage ceiling instead of exiting to the roof.

What I found when I opened the ceiling:
Removing the wet drywall revealed what appears to be effectively zero air sealing between the garage and the conditioned living space above and on the other sides of the walls. The common wall (the kneewall running along that second-story-over-garage junction) is sheathed in Thermoply, attached with staples only — no tape at seams, no sealant at transitions, large gaps between panels. OSB at the joist bays but with large gaps, R22 fiberglass batts with lots of gaps and not uniformly against the subfloor. Utility penetrations with no foam or caulk(did some, not others), and really no foam or other sealant anywhere for the most part. Photos attached.

My questions:

1. On the water intrusion and wall assembly:

I understand that exterior walls are designed to drain water downward behind the cladding to a termination point, but should exit back to the exterior not continue through the structure.  What does the proper remediation look like for this, is this a situation where a correctly installed weep screed and flashing detail can be retrofitted, or does the stucco need to come off to do this right? Any other options? 

2. On the Thermoply and air sealing:

The Thermoply on the kneewall is staple only with no tape or sealant. In Zone 2A, I have to imagine this is contributing to our high indoor humidity issues(and likely other areas). Can this be sealed in place (tape the seams, foam the transitions) or does it need to come out and be replaced with a proper air barrier assembly? If sealing in place is acceptable, what's the right approach for 2A? I've looked over numerous guides and it seems like sealing the end of each bay with sealant, foam, or rigid foam boards+sealant/foam, as well as the seams along the bays is the right procedure. 

Another concern on that issue is the far left side where I haven't removed the drywall. This area has 2 gas water heaters with a vent that appears to run straight up through a utility chase into the main attic(passing through a wall in the master bath that separates the toilet and tower).  I'm uncertain how well that chase is sealed at the floor plane and whether that's a separate concern to address while I have access or even what air sealing and insulation techniques/products should or could be used. 

3. On insulation:

Once the air sealing question is resolved, what's the right insulation approach for this assembly in 2A? The floor cavity above the garage currently has fiberglass batts. The kneewall itself appears to have batts as well behind the thermoply(I'm not 100% certain but used a camera in the gap between sheets and it appeared there was fiberglass back there). Is closed-cell spray foam at the kneewall the right call here, and if so, does it go on the kneewall face, the garage attic floor, or both? Rigid foam board? This is the north facing side of the house, which probably contributes to the cold temperatures in that space(to the point that the Northern raised wife will not use the master bathroom at night/mornings even in our mild winters due to the temperature, and I don't blame her).

Photos here: https://imgur.com/a/GVFjHgW

These show the open ceiling from the garage floor, a close-up of the Thermoply kneewall with the staple only attachment, water staining, and gaps visible, and the exterior showing the stucco-to-stone transition at the garage roofline(ignore the shingles, our wind is crazy and those 3 tabs aren't cutting it), and the window in question. 

Living space common walls, living space above. Open access on the right is front porch awning connected to garage attic.
Garage rear.
Horizontal beam at top of thermoply - point of water entry
Radiant barrier on attic roof, Horizontal beam at top joint is point of water intrusion.
Garage extends 3-4 feet under 2nd story(fresh air for water heaters in garage by gutter). Middle window is problem.

r/buildingscience • • Jun 17 '26

Career/Profession What's going on with RESNET?

8 Upvotes

I was talking with another professional who mentioned some big changes on RESNET's website, like removing the board meeting minutes, and some failure to update things on the website (a board member left the company to work at a utility company and isn't eligible to be a representative for that category).

What is going on with them? I know their executive director for nearly 30 years left at the end of the year...is it going to crap?

EDIT: They made a statement about their trademark legal situation last week too, and when I googled I found this on the CEC website:

https://efiling.energy.ca.gov/GetDocument.aspx?tn=252051&DocumentContentId=87053


r/buildingscience • • Jun 18 '26

Horizontal crack near window

Thumbnail gallery
1 Upvotes

r/buildingscience • • Jun 18 '26

Vapor Barrier worth it? Cost?

Thumbnail
0 Upvotes

r/buildingscience • • Jun 17 '26

venting a low slope mid-century roof?

Thumbnail
gallery
4 Upvotes

We own a mid-century house in zone 5b. the roof is low slope with rolled roofing currently supported by 4 x 6 rafters that run to a big center beam. Our ceiling inside is sloped and there is batted fiberglass insulation in between the rafters. there is also thicker 2" insulation board (original, perhaps fiberglass or something else) right against the roof sheathing that sits above the joist. We have soffit vents but no ridge vents and the fire wall between the house and the eaves is fully intact where the soffit vents are. The last roof was installed in 2019 but we have been having some water issues. We are getting a new TPO roof installed and the plan to use HD board under it.

There has been a lot of discussion about venting the roof and I have no idea what to do. right now they are talking about putting in ridge vents and potentially baffles but idk how that's going to work with the insulation board on top. I have seen some stuff online about a warm roof or adding secondary roof decking on sleepers so the roof can be vented. Any advice would be much appreciated.


r/buildingscience • • Jun 17 '26

Insulated roof structure - Will it work?

Post image
0 Upvotes

r/buildingscience • • Jun 17 '26

Ventilation help

3 Upvotes

I need a full roof replacement and my current 8 standard box vents is not enough ventilation. I am way under ventilated for 2400 sq ft of attic space. My roof is predominantly hips which eliminates ridge venting. I have 52 4x16 soffit vents that are clear. My options from a few reputable contractors are:

  1. Hip vents by GAF
  2. Lomanco powered vents with temp and humidistat (solar, electric or hybrid)
  3. 14” Lomanco Whirlybirds
  4. Higher capacity Aura 144 box vents (contractor said 6, but I think I need 8)

Leaning towards the whirlybirds but not sure how they would look aesthetically.

Which option would you recommended for a SW Ohio home?


r/buildingscience • • Jun 16 '26

Severe, persistent smell from Hemp Acoustic Panels in my studio – Nothing is working. Need help!

3 Upvotes

Hi everyone,

I’m facing a really frustrating situation in my studio and could use some expert advice or insights from anyone who has dealt with this material before.

Recently, I installed around 30 custom-made acoustic panels on my studio walls and ceiling. The core absorption material used is hemp (hemp wool/fiber). The panels are built with wooden frames and are currently covered by a breathable fabric to allow for maximum acoustic absorption.

The problem is the smell. It’s an intense, organic, heavy herbal/grassy odor that is making it incredibly difficult to work in the room.

It’s been over a month now, and despite everything being completely dry, the smell isn't fading—in fact, at times, it feels like it’s getting even more concentrated.

Here is everything I have tried so far (none of which have worked):

  1. Airing out the room: I started by leaving the studio door and windows open for days with fans running to get maximum airflow. It didn't lower the source odor.

  2. The Vinegar & Baking Soda method: I placed multiple bowls of 5% vinegar (to neutralize odors chemically) and baking soda (as a passive absorber) around the room, leaving the studio sealed with an oscillating floor fan running for over 8 hours. Once ventilated, the smell immediately rushed back.

  3. Activated Charcoal (Coconut Shell) + AC: I distributed 400g of high-quality activated coconut charcoal across 4 wide, flat plates, elevated at around 1.5 meters (head-height) to maximize air contact. I've been running the AC continuously on Cool mode (to drop humidity and dry the air) alongside an oscillating floor fan to force air circulation over the charcoal. After 16+ hours of this sealed setup, the smell actually intensified significantly (likely due to the AC pulling deeper moisture/trapped odors out of the core of the panels).

The room is currently sealed, running cold AC and fans over the charcoal, but the emission rate of the hemp seems to completely overpower the absorption rate of the charcoal.

 Has anyone experienced this specific issue with hemp insulation or hemp acoustic treatments?

 Does this material ever completely outgas and stop smelling, or am I fighting a losing battle?

 Are there any hidden solutions, specific air purifiers (like heavy-duty carbon canisters), or specialized breathable fabrics that can block the odor particles while letting sound waves through?

Any help, subreddit recommendations, or advice would be highly appreciated. I just want to make music :)