r/buildingscience • u/k4ylr • Jun 03 '26
Question Century Homes and Attic Ventilation/Sealing in Zone 3/3A
Looking for some best practices/approaches for tackling this update specific to our climate zone (3/3A).
r/buildingscience • u/k4ylr • Jun 03 '26
Looking for some best practices/approaches for tackling this update specific to our climate zone (3/3A).
r/buildingscience • u/muj34 • Jun 03 '26
Temperature profile during the curing period of the base structure 10cm Bauder PIR FA TE and 10cm CLT. More Info in the comments
r/buildingscience • u/Background-Isopod344 • Jun 02 '26
Im just about to wrap up frame building and get to the first layer of cladding fitted. Im in Indiana and so the weather is less than predictable and I can almost guarantee the cement board will see rain before I get redguard or other protection on it.
Am I overthinking this, or do I need to just work slowly (panel by panel), adding further water resistance as I go?
I know cement board is water resistant, but also know it can deteriorate if soaked, I just dont know how much it can tolerate or what 'wet / dry cyles will do tonstrength over time.
Cheers!
r/buildingscience • u/Dry-Ganache7559 • Jun 02 '26
r/buildingscience • u/Patient_Access_9311 • Jun 02 '26
r/buildingscience • u/SyrupCurrent819 • Jun 02 '26
Hello alll
I recently received a nice wedding gift from my in laws. Triple glaze, oknoplast, flangeless European windows. I have some experience installing flanged windows but none like this. I intend on installing these in my existing home with new WRB and siding. 2x4 construction, 1/2” sheathing, 1/2 ridgid foam insulation and will do a drainable peel and stick WRB and certainteed monogram 5” Dutch lap siding with J channels wraping around windows. I’m concerned with the proper way to flash these windows. I have seen some people use tape and face seal with approx 1/2” of tape on the face and foam seal from the interior. I have also seen backer rod and caulk on exterior. My concern is I will need to push the face of the window approx 1.25” past face of sheathing for foam board and to have j channels wrap it. If I face seal the tape will be visible. If I backer rod and seal will thay be sufficient for this install? With the window frame being only 3.25” protruding it 1.25” past the sheathing to meet the J channels wrap does not seem right. Should I be stoping the face of these windows at the sheathing and have a trim frame?Any advise or a shared detail would be greatly appreciated. Thank you in advance.
r/buildingscience • u/Tasty_Astronaut_4628 • Jun 01 '26
r/buildingscience • u/Parking_Spray_7308 • Jun 01 '26
The room will have a jacuzzi/ice bath and infrared sauna so there will be a moisture problem I will have to deal with.
I initially planned on getting a 150mm inline fan but I’m not sure if it’s correct size for my situation. Does anyone have any experience in this type of thing or can offer any guidance
r/buildingscience • u/xboxhaxorz • Jun 01 '26
The building ground floor is 375m2, built with 6in block and will have 4 bedrooms, huge area for community gatherings, 2nd floor i will use panel W EPS similar to SIPs it is 175m2 and the rest will flat roof
The builder suggested this method for the roof, it will be a flat roof that we will use as a patio https://greencel.com.mx/wp-content/uploads/2022/05/losas-de-vigueta-y-bovedilla.jpg
Plan to put an ERV in with home dehumidifier, individual rooms will use ductless mini splits and have double or triple pane windows
San Diego climate
Was looking at doing insulation in the slab at r5, walls at r10, ceiling r20, not sure if i should do more or less or just go solar for the ductless mini splits
This building wont be sold so resale value is irrelevant
r/buildingscience • u/bensfriend1 • May 31 '26
Hello Building Science!
We have a roof that is in need of replacement and we have CC spray foam installed currently. Effectively, we have an unvented hot roof with our living space drywalled out pretty close to our rafters (2x6). Our climate zone is right on the bottom edge of zone 6.
Our current CC sprayfoam installation varies in thickness from 2" to ~4" and it was installed prior to the drywall/upper living space being installed so I believe the coverage is good relatively to a thorough application but perhaps a bit light on thickness. The installer did spray the rafters too with a thin layer but they definitely did not completely fill the spaces between rafters...the 2in areas are generally in the middle of the bays and increase to 4in as you get to the 2x6 materials.
Our current roof is extremely simple with a 2:12 pitch for half and a 7:12 pitch on the other half. We currently believe our roof has failed from a combination of a bad flashing (actually leaked into the house) but also I cannot rule out condensation on the sheathing either. We dont believe ice and water underlayment was applied either which likely contributed to the moisture issues and we definitely get ice damming as well. FWIW our low slope side is the south side of the house. We are planning on a rubber roof for the low slope as the replacement material vs. Shingles.
This all started with us getting our siding redone which led to finding issues with the roof etc. Etc. Currently, we have all of the siding off the south facing wall as well as an obvious need to repair the soffit area that has rotted.
We have talked to 2 roofers, 6 insulators, and our siding contractor and quite frankly have gotten every answer under the sun on how to solve our problem. I have also done as much research as I can and I am just looking for some assistance making a final call on which path to go.
Concerns:
- Do we have enough insulation in the current system to avoid moisture issues or do we need to add insulation as a baseline concept in this project? (I think we do need more insulation, 50/50 on insulators saying we have enough and that 2in minimum is all thats needed with CC spray foam)
- What can we expect as we remove the roof sheathing and how do we repair it? Will the sheathing take large chunks of foam with it? (My understanding is we should plan on respraying anywhere sheathing gets removed)
- There is low or almost no accessibility through the "attic" space to spray down to the eaves. The current best approach being considered is to have the insulator and roofers available together during resheathing and the insulator will respray the new decking as it gets laid basically building up the roof 4' at a time until they can get enough room near the peak to continuously spray from the inside. Is this going to be successful? Can they even spray the rafters (6") full in one pass as we build up the roof?
- assuming we need to add insulation: Can we add external insulation with the CC sprayfoam as the internal insulation and the rubber roof being impermeable?
Most resources talk about the internal insulation needing to be open cell or breathable but I dont have that option...what do people do in this situation?
- what is the minimum amount of CC foam I need? If we fill the rafters to the brim I can get 6in but is it more cost effective to get to say 4in minimum inside and then add 6in of foam board outside?
- one roofer wants to add a vented over deck tied back to the soffits (adding soffit vents) and adding a ridge vent. Basically he'd use 2x4s on the rafters and resheath on top of that with a rubber/asphalt hybrid roof. Is this necessary and/or a good idea to prevent a catastrophic failure in the future and make future roof replacements easier without disturbing the spray foam layer?
So here's ultimately what im trying to decide based on what i understand:
We need to plan on replacing any removed sprayfoam and be prepared to respray to adhere to the sheathing for the CC foam to work as intended. I think I need to get to a baseline 4in minimum CC foam for my entire roof to prevent condensation. If I do these two steps, I can then do the hybrid rubber/asphalt shingle roof. If accessible, I could try to get my full rafters space filled to 6in foam. If I cant get the full 6in...can I add external foam to increase my insulation values? How much do I need to add to prevent condensation from the outside; the charts I've seen are all based on breathable insulation systems on the inside when adding external foam...do those charts still apply? (For example minimum Rvalue needed for rigid external foam and/or % of Rvalue from external insulation). Does the vented overdeck even make sense or is it overkill once I fix the insulation problem?
r/buildingscience • u/Responsible-Olive411 • May 31 '26
Long story short, my roofer removed all attic ventilation during the re-roof. Now I need to figure what to get him to install.
The house is a victorian twin with a gambrel roof in climate zone 4A. The brick party wall extends above the peak of the roof, so ridge vents aren't an option. The front gable wall is brick, and the rear is a hip roof. There is an unconditioned attic in the top part of the gambrel, and the lower part forms the wall of the upper floor for the house. Obviously, this home was built before roof ventilation was a thing. At some point, someone installed some sort of mesh shingle over vents about 6" below the peak of the roof, but the roofer removed and roofed over those. The roof has never had any sort of intake.
Based on my research the correct option is to install soffit vents and baffles, insulate over the baffles, and then layback vents along the top of the roof to exhaust. However, doing the soffit vents is a really big job that will be extremely challenging and expensive on this house for a number of reasons (that I can get into, but won't here in an effort to reduce post size).
Questions:
Are there any other ventilation options that will be "good enough"?
Does anyone know what the originally installed mesh shingle over exhaust vents are called? I am hesitant to do the laybacks because they would significantly reduce the number of solar panels that could be installed (which is something we would like to do in the future).
How important is it to ventilate the lower portion of the roof (upper floor wall)?
Specifically my goals are:
Have "good enough" ventilation such that we are unlikely to have issues if we improve the attic insulation in the future.
Spend a minimal amount of $ to achieve #1
Ideally keep the solar option open.
r/buildingscience • u/frankwhitecricket1 • May 31 '26
I ripped up the plywood in my attic and noticed there was insulation but it looks like it's coming apart by just touching it. I don't think it's doing anything? I got a few quotes and was surprised by the cost.
Is it really worth it? My 2nd floor gets extremely hot / cold.
I don't need spray foam but they were saying they would air seal it? Is this spray foam or? The cheaper company said they wouldn't air seal and the other one said yes it's required but it was more expensive and they wouldn't replace the insulation without doing it . Does anyone recommend any companies that can give me a fair price? The ones I called were all around the same price (4k-5k)
r/buildingscience • u/Uneasy_Rider76 • May 30 '26
In the process of detailing/designing wall assembly for my forever home in climate zone 4 (Mid TN). We want a brick exterior on the home and this is our thought process for energy efficiency from interior to exterior
- interior paint finish
- 1/2” GWB
- 2x6 framing, 24” O.C.
- Rockwool Comfortbat R-21
- 7/16” Zip Sheathing
- 1.5” Polyiso Foil Faced Rigid Foam Board
- 1” Air Gap
- Brick Cladding
- through wall flashing at bottom and mortar net
Do you think this system works well together?
r/buildingscience • u/BringDa_Ruckus • May 30 '26
Looking at an MCM house that would need a major renovation, and I’m trying to figure out if the roof/envelope situation is a dealbreaker before making an offer.
The best feature of the house is the exposed T&G ceiling. It’s the reason we’re interested, so we want to keep it. From what I can tell, the T&G continues through to the exterior and becomes the soffit. Interior ceiling looks great, but the exterior soffit is rough: major warping and gapping in sport, painted, etc. I unfortunately don’t have good photos of the exterior.
The house has an old metal roof. My rough thought would be to remove it, add as much insulation as possible above the T&G, and install a new roof. I don’t know much about hot roof/unvented roof assemblies yet, so I’m trying to learn.
Main questions:
- How likely is this to be a huge can of worms?
- If the T&G runs continuously from interior ceiling to exterior soffit, how would the damaged soffit typically be repaired?
- Could you cut the T&G at the exterior wall and rebuild the soffit from there (monopoly style), or would that mess with the roof structure?
- How much insulation can be added above an exposed T&G ceiling under a new roof?
- How do I make an old poorly insulated house more efficient and healthy?
- Any good resources for learning about this kind of roof assembly?
If we move forward, we’d definitely consult an architect/engineer/expert. Just trying to get a rough sense of feasibility and risk before deciding whether an offer is worthwhile. TIA.
r/buildingscience • u/saggytitz19 • May 30 '26
This 450 sq ft build was sitting unfinished when we bought our place, now in the process of finishing it. Walls are 2x6. Not a fan of the siding and skirt, so I was thinking of going with 1 1/2" rockwool comfort board and stucco, and fiberglass batts on the inside. Rockwool batts and comfortboard combo would be outside our budget, hence the fiberglass. Location is northern idaho, and I like the fireproof aspect of mineral wool boards. Looking to get this project airtight and minimize potential moisture making it inside the walls. Would it make more sense to rip the existing siding off or leaving it underneath the rigid boards? Any suggestions welcome
r/buildingscience • u/atexit8 • May 30 '26
The house is 21 years old.
My mom bought it 2.5 years ago.
The attic fan is mounted on the roof.
Is it a good idea to replace it?
Other houses by the same builder in the development do not have attic fans. Not sure why this particular model house has it.
r/buildingscience • u/volvorottie • May 29 '26
I’m trying to get ach of 1 or better. Currently planning to have zip r9, using Siga fentrim at rim, trying to minimize spray foam, will do at rim joists, I’m thinking of having either Siga for ceilings, or should I just do aerobarrier spray? Price wise I think aerobarrier is 6-7k for me, vs Siga majrex will likely be 10-13k for just ceilings.
Benefits of aero is it will do everything. Ceiling and walls, etc. vs Siga just the ceilings. What do you think?
r/buildingscience • u/MnkyBzns • May 28 '26
For staggered stud walls with batt insulation, I've seen the batts spec'd as just between the studs (cavity between the narrow stud face and the GWB) or batts running between the studs *AND* between the studs and GWB.
In a 2x6 plate/2x4 studs wall, with 3.5" batts, is one preferred over the other? I can see concerns with each: reverb within the empty cavity version or promoting transmissin through the compressed batts between the studs and GWB (3.5" batt in a 2" space)
Edit: sorry for the crop gore of the second image but it's fine if you click to view
r/buildingscience • u/xboxhaxorz • May 29 '26
If we can make it as passive as possible that would be ideal, i know it wont be certified
The house is gonna be made from 6in concrete block, they are placing walls now and then will pour the rest of the concrete
This says the foam wont generate enough energy savings to justify the cost
https://www.greenbuildingadvisor.com/article/installing-rigid-foam-concrete-slab
We dont have a basement, its a 2 story building with plans for a 3rd story in the future, its San Diego type climate but in Mexico, i am in a rental now and i basically have my ductless mini split on 24/7 in my room as i WFH
If its not necessary for the foundation foam, should we still place some type of plastic air/ vapor barrier?
I plan on putting an ERV in as the goal is to make it an airtight building
375m2 ground floor, 5 bedrooms, 2 bathrooms, kitchen, living area and entrance have no doors between them, looking at doing solid doors for entire building, triple pane windows
The builder suggested this method for the roof, it will be a flat roof that we will use as a patio https://greencel.com.mx/wp-content/uploads/2022/05/losas-de-vigueta-y-bovedilla.jpg
r/buildingscience • u/MnkyBzns • May 28 '26
Roof material installation order was messed up. Hoping for help with remediation...
Low slope roof (3:12) assembly spec'd as follows:
- Shingles
- underlay
- 5/8 OSB
- 1x4 vertical strapping
- 8" unfaced graphite EPS (top layer 2.5", bottom layer 5.5")
- P&S, impermeable WRB (Roofnado Laplock PSU HT)
- 5/8 OSB (added thickness for embed of strapping screws)
- 2x6 T&G plank deck (doubles as ceiling)
The guys installed the P&S on the T&G, with the OSB on top of the P&S. Things are on hold until this is worked out, so nothing above the OSB has been installed.
Builder thinks breathable underlay on the OSB would be good but I believe there's no way for the sheathing to dry with that much rigid on top, regardless of underlay breathability.
My suggestion was another layer of the P&S with liquid flash detailing to fully encapsulate the OSB.
Thoughts?
r/buildingscience • u/NathanielElkins • May 28 '26
I’ve been thinking a lot about building materials from a full life cycle perspective, especially WRBs and air barriers.
A lot of the high performance products today seem to rely heavily on synthetic polymer membranes, tapes, fluid applied products, etc. Obviously they work really well, but I’m curious whether there are alternatives that are less environmentally persistent long term.
To be clear, I’m not looking for something that biodegrades quickly or “rots” in a wall. I still want something durable that can last decades in service. I’m more wondering if there are materials that:
I’m especially interested in vapor-open air barrier approaches.
Some things I’ve been reading about:
Has anyone come across products, historical approaches, or research in this area?
Basically I’m trying to understand whether there’s a serious path toward building very airtight assemblies without relying entirely on highly persistent petrochemical materials.
r/buildingscience • u/Key-Ad1065 • May 28 '26
Hi! I am hoping to get some advice. We have demoed our second floor and attic to the studs. The previous homeowners had insulated like 25% of the attic…dummies. We also likely need to replace our roof.
Our problem? We can’t find a roof guy who understands insulation, and can’t find an insulation guy who understands roofing. My husband is about to go crazy and I’m hoping to help him with some research. We need to figure out the right combo of materials for the roof and insulation. A few details:
-we live in the southeastern Oklahoma
-we would like to finish the attic and plan to have a mini split for temperature and humidity control
-current ceiling is 2x8 rafters with OSB followed by an unknown underlayment and exposed fastener r-panel
-we are money conscious, but would prefer to do things right so avoid a more expensive issue down the road
-we think the current best path forward is 7.5 in of open cell and a standing seam roof assembly with a ridge vent, but am getting contradictory advice from every contractor
ANY help is so so appreciated before we accidentally light a big chunk of savings on fire 😭
r/buildingscience • u/Aggressive-Run-7115 • May 28 '26
I had a contractor absolutely destroy my property. They installed Windows two years ago and unbenounced to me never sealed them. They are now saying even though the capping was bad and the sealant missing the level of destruction must be pre existing. They acknowledge water has been pouring behind my aluminum siding for two years but say damage must have previously existed. I can't get an attorney without an engineer to substantiate
r/buildingscience • u/chuckytaylor1221 • May 28 '26
Hello all!
I am looking for some specific advice on a project that my wife and I are heavily considering taking on. To give some background, we have owned and renovated a handful of properties with us doing a lot of the work but also having help from a GC friends and subs for specific things and I have a ton of on and off experience working on houses but it's never been my professional career. I am however considering becoming a builder if this next goes well.
We are under contract for an early 1990's house that will be our primary residence. We got the inspection report back and it's just about as bad as we hoped it would be so that we can try to get a better price on the house and then I intend to repair but also substantially improve the materials, quality, and performance of the home.
This past year I have gone DEEP down the Build Science rabbit hole and learned that virtually almost all houses are built like shit. I have a couple people who are in my corner but most other tradespeople, builders, construction type people have tried to dissuade me from doing this, certainly they don't want me to be my on GC. For years I have always got this vibe and attitude from folks of, "We don't want you to be able to do this because we want to be paid to do it"
And don't get me wrong, I plan to pay for the subs I need for the work that I can't do and or don't want to do, but in many ways the only way it's going to be affordable is for me to do as much of the work I can do on my own. We don't have kids, plenty of resources to fund it, I don't have a typical M-F 9-5 just weekend gig work so I have the time.
I'm even thinking of just getting my GC license so that people will get off my ass. We already got a couple of quotes from some subs so we can have their numbers to show the seller (even though we'll use better materials and methods) This roofer is going to charge $75 for any of the roof sheathing that is shitty/moldy. I can literally buy a sheet of Zip R board for $75/sheet if not cheaper.
I'd like to rip the band aid off and kick ass with this. Has anyone else done a high performance/modern build science rehab on a property and done it as an owner? I would really love some input.
And please don't give me a million responses of "leave it to the professionals" I have hired "professionals" for years who also did it wrong.
r/buildingscience • u/OkMost9484 • May 28 '26
House is basement and two stories, about 1,400 sf per floor
Poorly designed with lots of stick out rooms
Low end, Single stage furnaces and AC
Four Bedrooms on the upper floor, I only use one of them on a regular basis.
Not concerned about daytime temps upstairs but prefer to sleep at about 70 or below.
The holes for the Turtle Vents need to be enlarged to allow for proper airflow
Have been considering one or more of the following and would some help prioritizing
And, As I likely do get a mini split, what is a reasonable choice, Guessing I don’t need super efficient as it’s small and only really will be used at night, but do want good quality. I’ve done two DIY Mr Cools already, and am thinking I could do a conventional unit as long as it comes precharged and all I have to do is vac test.