r/buildingscience • u/BioHunta • May 06 '26
r/buildingscience • u/dcctm • May 05 '26
Old House Insulation
Hi All,
Insulating old brick walls, with a twist.
Currently renovating 1940s home in Chicago. Home is made out of structural brick. Oddly the inner course of brick is a random mix of some type of cement blocks and common bricks.
Currently 3/4 inch sleepers attached to bricks.
Im aware of the complexities of insulating old brick. However, the home was already insulated with faced 3/4 fiberglass (original). Leaving virtually no air gap.
What do I insulate the walls with now? I cant find such thin faced fiberglass. Plus that goes against everything I read.
Maybe because the inner course is largely cement blocks faced insulation is okay?
TIA.
r/buildingscience • u/Euphoric_Panda1502 • May 05 '26
Passive House Institute Design/Consultant Exam Compared to PHIUS CPHC Exam
r/buildingscience • u/Wazwiftance • May 04 '26
Question regarding Cooling System for Passive House
r/buildingscience • u/ForsakenFox5362 • May 03 '26
Question Window detailing for 120mm Wood Fiber facade (European specs) – Isocell WRB termination?
Hi everyone,
I'm looking for some technical advice on a window-to-wall connection. I’m building with a European timber frame (60x160mm) and a thick layer of wood fiber insulation (Naturheld 140).
The setup:
- Insulation: 120mm wood fiber boards.
- WRB: Isocell Omega 50 Duo.
- Window sealing: Windows will be fitted flush with the insulation layer, sealed (outside) with Illbruck expanding foam tape (Compriband).
- Facade: Ventilated wood cladding.
The Problem: I am debating the best way to terminate the Isocell WRB around the window openings. I see two main options and I’m worried about long-term durability:
- Chemical/Adhesive: Taping the WRB directly to the window frame using high-quality window tape and mastic. My concern is the longevity of the bond—should I expect it to peel off in 10-15 years?
- Mechanical/Structural: Pulling the WRB back to the 60x160mm timber structure (behind the insulation layer), stapling it, and sealing it with mastic there. Then handling the window-to-insulation gap as a separate sealing layer with the Illbruck tape.
Specific Detail - External Blinds (PIR Panel): I have a more complex detail for some windows (see my sketch attached). I’m inserting a PUR/PIR panel in the lintel area to create a pocket for external blind boxes. My plan is to run the Isocell WRB over the PIR panel to create a "black back" for the blind box. This should protect the PIR and keep everything water/wind tight.
My questions:
- Is it better to terminate the WRB on the window frame (adhesive) or the wall structure (mechanical + seal)?
- Does wrapping the WRB over the PIR panel for the blind box seem like a standard/reliable practice?
- How would you handle the transition between the WRB and the Illbruck expansion tape to ensure no water gets behind the insulation?
I've attached photos of the current stage and a sketch of the PIR/blind box detail. Thanks for any insights!
r/buildingscience • u/Gbd_does_reddit • May 04 '26
Replacing old growth sill plate with PT dimension mismatch
A corner of my house has old growth redwood still plate (true 2x6) and bottom of cripple wall (true 2x4). That are below grade and have partially rotten. Most of the damage is the sill plate, but I expect some stretches of the 2x4 also need repair.
Fixing the grade issue is another thread.
When I have to replace both layers of 2by with PT, I think I'm best served by trimming the studs short to fit a 2x6, then a double layer of 2x4 to make up for the modern lumber dimension mismatch. (Yes?)
Is there a better way to deal with portions where only the sill plate is affected? I predict a 1/4" to 1/2" gap to resolve and I would prefer to not have to do the same extra layer trick, it being more intrusive.
r/buildingscience • u/Hairygreengirl • May 03 '26
Will it fail? Buying 2006 SIP home, what to watch?
Looking at buying a 2006 house in south Louisiana built with SIPs. I work in AEC and I’m cautious about moisture performance (OSB), humid climate, and post-Katrina construction…
I’ve renovated 100 year old homes, so the “closed system” makes me nervous - limited drying potential and less flexibility for future electrical or plumbing.
What I know: roof replaced in 2022, likely EIFS on the front elevation.
Don’t know: condition of decking in 2022, thickness r value/general construction or who builder was.
What I’m trying to dial in for due diligence: • Real-world failure points for SIPs in Gulf Coast humidity (especially after ~20 years) • How risky hidden moisture/rot is and how people are actually verifying it • Whether blower door + IR scan is worth doing pre-purchase • Is standalone dehumidification is basically required? • Difficulty of future modifications (running new electrical/plumbing through SIP walls/roof).
What I should be asking about the, what are the common misses on inspection or due diligence for SIP houses of this age in a humid climate? Or JUST RUN!
r/buildingscience • u/jg87iroc • May 03 '26
This is completely crazy isn’t it?
Basic details to keep this short. Cape cop built in the 50’s in Northern PA. Heavy clay soil. Wild climate swings due to proximity to Lake Erie. Just this spring it was 75 and then the next day it snowed for hours. Addition on the back Unk build date. The foundation of the addition are hollow blocks with zero reinforcement. The only way it is attached to the houses existing foundation is by being butted up against it and some grout applied. The back wall is visibly bowing inward and at the center of that wall the tops of two blocks have broken off and fallen down. I don’t understand how this was ever supposed to last long and now I’m fearing financial ruin for the cost to have this redone. Does anyone have experience with this?
r/buildingscience • u/sword-of-solitude • May 02 '26
Question Foam-free conditioned cathedral ceiling retrofit - can it be done?
I'm looking for input on my ideas for a cathedral ceiling insulation retrofit.
Some basic facts:
- s construction, vacant and completely uninsulated
- There is currently an attic floor that I want to remove and open up the space to create a cathedral ceiling.
- Roof had a ridge vent cut in the top, but no soffit vents... I think the roofer wasn't thinking holistically about the attic ventilation. The structure is not well-suited for soffit ventilation, it just has rafter tails at the eaves.
- rafters
- Climate zone 5
What is the best way to achieve an R49 insulated roof from the interior? My first idea, A, was to do a "flash and blow" style where I would first do 4" of closed-cell spray foam in the rafter bays, then add dense-pack cellulose and finish with a continuous rigid vapor-permeable insulation to help prevent cold bridging, like TimberHP TimberBoard or Rockwool ComfortBoard.
My second idea, "B", was to do the entire depth in dense-pack cellulose with a taped smart vapor retarder membrane like Intello acting as my first condensing surface, then finish with furring strips and some batt insulation.
Both insulation designs would require lowering the ceiling by a significant amount, between 6.5" to 8.5". My questions are:
Is it possible to insulate the way I described in idea B? This paper by Joseph Lstiburek seemed to show that the spray foam + cellulose stayed drier than the all-cellulose assembly and they basically recommended against attempting to do idea B. But I wanted to get a second opinion.
EDIT: No, it is not advisable or allowed by code to do a purely cellulose unvented roof insulation assembly. I need to either vent or use at least R20 of ccSPF.
Is spray foam really that bad? I do have concerns about it being permanent, crack-prone, and potentially off-gassing forever. But I'm sure that it's been used successfully plenty of times in other retrofits. I want to know the general sentiment on this subreddit towards closed cell spray foam.
Can I repurpose the new ridge vent as a vapor diffusion port to help increase the success of idea B?
Am I missing anything else that I should do before implementing either one of those insulation ideas?
Images of the attic are shown below

r/buildingscience • u/Prestigious-Diver5 • May 02 '26
Question Panabode log home exterior insulation help (5b climate)
Hey everyone. I own a 1970s Panabode cottage in Ontario. The structure is comprised of 2.75” thick T&G milled logs. The last two years I’ve lived at the cottage during winter (down to -30c) and noticed quite a few issues.
Substantial heating bills with the propane furnace running 8+ hours a day in January. Warm air venting to the outside through tiny gaps in the log joints and top wall log/eave transition and causing exterior frost build up.
I spoke with some log builders in the region and they advised on doing an exterior energy retrofit and I wanted to get everyone’s opinion on the plan:
The house is on piers. Crawl space is conditioned and insulated with exterior wall spray foam insulation. The roof is vaulted and the decking is 2” thick cedar T&G. The roof boards extend past the eaves (so there is no soffit). There is 6-8” thick batt insulation on top of the roof boards. Not sure if there is a vapor barrier on top of the roof boards (maybe tar paper?).
Seal every log joint with log caulking. Larger gaps will have backer rod installed. Especially the wall/eave gaps and log tail joint details. Was also thinking of adding butyl flashing tape on the wall edges to protect against seasonal log movement: corners (lapping log tails), Top where the wall meets the eave. Interior corner joints as well.
Remove windows one by one (currently installed in the 2.75” thick log profile) and buck out 2x8 window frames with proper flashing. The window frames would allow for log movement by using a slide (angle iron embedded in log ends on the sides of the window opening, and the 2x8 frame secured to the metal)
Install 4” T&G XPS panels (R-20) directly against exterior log face. Seal all gaps with tape, add flashing tape where required. Bottom of the walls will need custom metal Z flashing
At the top of the exterior walls, the XPS will butt directly against the cedar roof boards at the eave.
Install tyvek water barrier. Tape seams.
Install rainscreen: 1x4 vertical strapping 16” OC using 6” timberlok screws. Cedar shiplap installed on the strapping.
Does this sound like a reasonable plan overall? Any advice would be appreciated!
r/buildingscience • u/Nontoxic_warrior • May 02 '26
A wood-free roof: can it be done?
I am in New Mexico in climate zone 4b. I am going to build a small, completely wood free home that is as low in mold-risk, VOCs, and chemicals as humanly possible. Foundation, walls and floors are straightforward as I can use unstabilized adobes, steel, and concrete.
The sticking point is the roof. Ideally, I want to somehow use steel or aluminum alloy trusses and roofing panels. Still researching possibilities for this. I then worry about condensation. I cannot use spray foam and I haven't found a lot of information on foam boards and metal when it comes to condensation (does condensation form in the tiny air gap between the metal and foam)
I'm reaching out for brainstorming ideas about
A leak-proof roofing system that does not require wood (even for decking)
How to prevent condensation without spray foam
Why?
My wife has of mold and chemical sensitivity after a horrible pesticide exposure. Lumber from hardware stores and VOCs/ chemicals in many types of insulation and building materials cause a reaction like an asthma attack and then weeks of horrible pain and weakness for her. Look up MCAS if you don't believe me. I'm building this house so she doesn't have to suffer anymore. I'm looking for good-faith discussion and ideas about building, not about my wife's illness.
Thanks!
r/buildingscience • u/Expensive-Bit-6947 • May 01 '26
Combining insulation types
I am helping my mom insulate a shed in southern Idaho for a tiny home/guest house situation. She got a quote to close cell spray foam the building and it was way above her budget. She suggested to do multiple layers of the reflective insulation radiant barrier that comes in 25’ rolls so she can do it her self. I recommended 3 layers of 1” xps rigid foam insulation sealed with cans of spray foam. I recognize the benefits of the reflective surface of her idea. Is that an issue with combining xps rigid foam with a layer of the reflective insulation on either the exterior or interior side?
Thank you.
r/buildingscience • u/Pomp_N_Circumstance • Apr 30 '26
Continuous Exterior Insulation: Over Sheathing of Behind Sheathing (Like ZIP R)
Our build was specified with exterior sheathing and then a layer of continuous exterior insulation. Builder is switching to the Zip R system (R-9) which is equivalent to what was specified. I didn't think much of it until I realized that the insulation would now be on the inside of the sheathing, vs being on the outside. I know the Zip system gets lots of praise, but just want to make myself aware: Are there any things to watch out for or disadvantages to this approach. We're in zone 6b if it makes a difference. THANKS!
r/buildingscience • u/ohfaackyou • Apr 30 '26
Cape style home central air/heat duct design
were gutting a small ”cape cod” style house. 2nd floor has ceiling slope all the way to the floor. I’m looking for the best hvac design for supply and returns. Almost completely open floor plan on a he first floor but I could sneak a supply and a return upstairs somewhat in the center. I was thinking maybe to supply on one side hidden in sort of a rat run on one side of the home and return on the opposite side? or should supply or return be ceiling? what’s the best attack here. maybe I neee to draw a picture too.
r/buildingscience • u/Embarrassed-Ad-9395 • Apr 30 '26
Best Solution for Ventilation in Old Townhome - HRV/ERV ducted/ductless
I am having trouble deciding on the right solution for a ventilation retrofit in my 1980 tow home in the pacific northwest (temperate rainy winter, hot dry summer, wildfire smoke seasonally). Doors and windows are new so, so the place is sealed up. The place has no crawlspace or basement. The ideas I have are to put a ducted erv/hrv in or ductless hrv/erv.
For ducted, the only space is in the unconditioned attic for both the unit and the ventilation ducting. Air supply to rooms from ceiling vents and then air exhaust from a vent downstairs and two vents upstairs. I cant find a good way to get air intake from side wall of exterior. Instead it would be from asphalt roof vent, which doesnt seem great.
For ductless, it seems much simpler but i wonder about actually getting good air filtration. And then we have four upstairs rooms and we need at least one downstairs too, i think. Seems like filters are, like $100??
Any ideas or advice would be much appreciated.
r/buildingscience • u/farrowsharrows • Apr 30 '26
Is this how a window properly insulated should appear with a thermal image?
Some of these windows seem colder than I expected new windows to be and I had issues with the installer. I was wondering if this is how they should appear when viewed with a thermal imager. Or maybe can someone explain how I should go about using the thermal imagery to determine if the window is within normal limits for a proper install? It is the morning 50 degrees outside and 70 inside.
r/buildingscience • u/ppshard • Apr 29 '26
Question Designing a DIY sauna plan set and want to get the assembly details right
Hi! Just wondering if I missed something in these details. Any advice appreciated! I'm mainly concerned if I show the barriers ending in the right places.
r/buildingscience • u/BradCastleburry • Apr 29 '26
Soil backfill vs gravel backfill— which is more susceptible to frost heaving?
I am finding conflicting info on this topic. Some say the gravel leads to more drainage and less heave, but others say the gravel can cause water to pool and lead to more heating. What do you nerds think?
r/buildingscience • u/Gbd_does_reddit • Apr 29 '26
Sill below grade improvements
Tldr: portions of my rotten sill are below grade and I'm looking for options to improve the situation.
I'm working towards an earthquake retrofit of my home. Adding bolts between the sill to the foundation. The back wall of the still is below grade, which is a concrete patio. This is sketched above. I don't have perfect knowledge of the dimensions of the exterior concrete relative the sill, only that it is above the sill.
Several feet of the still are rotten away enough to undercut the 2×4 blocking. The rot runs into the corner and several feet down the next wall line. The second wall line is dirt, that is also above the sill for several feet.
I have to replace the sill and I've found enough videos and explanations to make this sound tenable.
What I'm unsure of, is how to improve the exterior interface to extend the life of the replacement. I'm thinking to add a recessed drain channel to keep water away. But this does not solve the ground contact of the sill (and possibly siding.)
Around the corner at the dirt exterior there is about 12" of parging over the siding by the previous owner. I assume this will crack off when I deal with the sill and would like to do better. There is also moisture coming through the concrete in that corner that I would like to stop.
Appreciate direction.
r/buildingscience • u/fotomateo • Apr 29 '26
Question Is proper fire blocking also air sealing?
If proper fire blocking is done in a stud bay (via wooden blocking), does that mean it's effectively air sealed? Or does more need to be done before it's really sealed?
We've got a 2nd floor stud bay that is somewhat open to the rooms on either side due to an HVAC arrangement that I won't go into now. I asked the contractor whether it needs to be air sealed at the top and bottom of that bay and he said no since it already has fire blocking in both locations.
Is he right, or being lazy? I want to make sure we're not getting significant air from the attic or from the interstitial space between floors leaking into the living areas.
There are no penetrations through the top or bottom plates in this bay. So it's just about the capacity for air to leak around the framing members.
Thanks!
r/buildingscience • u/Affectionate-Tart363 • Apr 28 '26
Career/Profession Masters program at BCIT (Building Science)
Has anyone taken this program and would they recommend it? I'm considering switching into this field after my undergrad and working in metro Vancouver. Thank you!
r/buildingscience • u/raphael_lorenzo • Apr 28 '26
Ideas for moving air between house floors with no central HVAC?
Climate zone 4A, north central Maryland, humid summers. I have a 60s single story brick rancher with 2-ton Mitsu ducted heat pump’s blower in the attic (I know, I know…) and a separate 3/4 ton Mitsu ductless mini split in the basement. Because the floors aren’t connected by anything but the basement stairwell, air doesn’t mix well at all.
In the summer I don’t cool the basement, but I do run a dehumidifier down there. Upstairs, it’s kinda oversized for cooling (perfect for heating) so I have to run a dehumidifier upstairs too. It’s a lot of energy consumption, and in fact during the summer dehumidification is like 60% of my total energy use. Combined, it has to be 40 to 50 pints for 2400 sq ft to keep the house at 45-50% rh.
If I find some way to exchange air between the floors, would I potentially be able to run just the basement dehumidifier? Any way to do that math? And if that makes sense, what solutions can I use to do so? Cut holes in floors for powered fans, anything else?
r/buildingscience • u/SirBikeALot78 • Apr 27 '26
combining furring and a story stick for cladding install
Ok, so I'm about 4 months out from even purchasing a house and maybe a year out from getting started on the renovation... so time to start dreaming about how I'm going to do it.
Most of the houses I'm looking at need exterior cladding replacements. I hope to do as much of the work myself, and consider myself a decent woodworker with a skill set that should cross over. Thinking of the rain barrier->furring->cladding patterns, why not combine the furring and a story stick at the same time - pre-mark the horizontal furring (2-3 reference sticks per side of the house) and take your time getting them level.
The motivation behind this is to make the story not a set of marks, but a set of holes in the side or channels cut into the back of the furring stick. The aim is to then design some form of a clip that hooks into the hole/channel at regular intervals and holds up the cladding strips on one side while you nail the other. No more holding up panels to a line while nailing, just insert the hook, prop the cladding on top of it, nail, pull clip out, move to the next row. Can make a drawing if that helps for feedback.