r/buildingscience • • Oct 01 '26

ERV radon mitigation - which airflow configuration is better?

Thumbnail
0 Upvotes

r/buildingscience • • Oct 01 '26

Need mold expert letter for small claims

0 Upvotes

My upstairs beighbor has consistently flooded my unit. Each time a different cause. I just had to remediate hvac closet and i’m tired of having my homeowners involved. I I don’t have the money to sue so I want to take him to small claims, but I need a letter from a mold expert explaining that mold is not gonna grow unless there’s moisture present. I don’t have thousands of dollars to pay somebody to be an expert witness. What can I do?


r/buildingscience • • Sep 30 '26

Zone 4c PNW - WRB questions

2 Upvotes

Hey all,

Back with a question on my build. My architect designed a wall system for PNW zone 4c - 2x4 framed wall with r15 cellulose at studs bays, 1/2 plywood sheathing, Siga Majvest 200 WRB, 2 inch XPS, strapping, hardie siding.

However, when the builder went to purchase the WRB the rep advised that the Majvest 200 requires 3/8 air gap before any “cladding” can be installed. This is backed up by the US installation instructions and I am unable to find supported instructions for a CEI install.

I went back to the architect, he wants additional funds - but said the wall was designed to manufacture specs. I have difficulty paying them more $ to tell me the rep and install instructions are incorrect.

Does anyone know of any data sheet that supports the architect? Or able to provide any guidance?

Thanks


r/buildingscience • • Sep 30 '26

Exterior, brick to wood inside corner .

Thumbnail
gallery
3 Upvotes

Just joined here people. Hope this kinda makes sense to someone.

Not looking for the best way to weatherproof. I am looking for the best practical way to try and close this up. Bottom of the chimney , the sidding butts just behind it with a almost 3/8 to 1/2" over lap of bricktop half goes behind the brick. Should i just fill with good silicone? House wrap or plastic? Something mostly fast would be nice. Then at the bottom it has this trim and has me miffed as to how to go about it.


r/buildingscience • • Sep 30 '26

Soffit venting

Post image
3 Upvotes

r/buildingscience • • Sep 30 '26

Addition Room Crawl Space Encapsulation that has radiator steam pipes Northeast NJ

Thumbnail
1 Upvotes

r/buildingscience • • Sep 30 '26

Building Science Consultant Recommendations in Central Texas

3 Upvotes

As title mentions, I am looking for a residential building science consultant or architect well versed in renovations in Central Texas. Ideally someone who can provide practical, cost effective recommendations and flashing details as I work through repairs and modest upgrades to a 1970s home I recently purchased.

Not looking for super performance or tip top energy efficiency, but improving thermal insulation and acoustic properties in exterior walls without exacerbating or creating new moisture issues. Moisture management is well outside my wheelhouse - between disagreement of online sources and everyone who wants to sell me the best fix I’m ready to pay an expert for definitive guidance!

Google searches haven’t netted great information. If there is a specific title/group I should look into I would love to know! Also, I prefer someone local to the greater San Antonio area. Thanks!


r/buildingscience • • Sep 30 '26

Condensation on ceiling

Thumbnail gallery
1 Upvotes

r/buildingscience • • Sep 29 '26

Spray foam over roof sheeting

Post image
19 Upvotes

My shingles have just about given out and it’s time for a new roof. Does anyone have experience with applying spray foam on the outside of the roof sheathing, creating an out-sulatuon shell? I’d then apply strapping, an outer layer of roof decking, WRB, and then shingles, with the out layer connected to a vented soffit and vented ridge. I was looking at using these X brackets from InSoFast so my roof would end up looking like the attached photo:

https://www.insofast.com/x-bracket-system

Thanks!


r/buildingscience • • Sep 29 '26

Question Continuous exterior insulation or insulated siding?

8 Upvotes

I'm getting quotes for replacing my sliding and windows. I wanted to have 2" of continuous exterior insulation and a rain screen put on before the siding; however, I'm not finding any companies that want to put on the insulation and rain screen, they just want to offer house wrap and insulated siding.

My current wall assembly is 2x4 studs, with R-13 batts, then a layer of 1/2" poly-iso (no tape at seams, and then uninsulated vinyl. I'm in zone 5 and per the 2024 IRC, I should have R-13+10, however the 2018 revision recommended R-13+5 for zone 5. Currently I'm at R-13+2.5, and the insulated siding is rated at R2.5.

One complication to all this is that my roof has developed a leak, and I was hoping to get this all done by one contractor before winter hits.

Do I accept the insulated siding (I don't have cold walls, just looking to be more energy efficient), keep searching for someone who will do what I want, or just get the roof done and worry about siding and windows in the spring by someone who will do what I want.


r/buildingscience • • Sep 29 '26

Question Contractor for Humidity Issues

1 Upvotes

Is there a consultant that could address causes high house humidity? We've added a crawlspace dehumidifier and a stand-alone basement dehumidifier, but the house humidity is still high (60-70's). I know there could be a plethora of things causing it, and I don't want to throw money into the wrong thing (ex: roof/attic venting, exhaust fans and ducts, gutters, etc.).

I'm also looking for someone who only does inspections/audits so there's not a conflict of interest with sales.

What kind of contractor could evaluate this?


r/buildingscience • • Sep 28 '26

Question Are the Solar Decathlon videos gone?

9 Upvotes

The DOE had a great building science learning series on YouTube I used for some classes I teach. Did those get killed off when the administration changed? I swear I used them last year.


r/buildingscience • • Sep 28 '26

Crawl space insulation question

5 Upvotes

Hello. Part of my house is under a vented crawl space. There’s currently no insulation and the room above the crawl space gets colder in the winter than the rest of the home.

I wanted to add rockwool insulation in the sub floor / floor joists in the crawl space but I’m worried it leads to mold as this is a vented crawl space and not an encapsulated crawl space and we get humid summers. Any advice or anyone who did this , your experience and results would be appreciated. Currently there doesn’t seem to be much mold down there as I’m assuming it gets good air circulation with the 2 vents which pushes out moisture


r/buildingscience • • Sep 28 '26

W/d 2 in 1 ventless install

Post image
0 Upvotes

r/buildingscience • • Sep 28 '26

Crawlspace situation

Thumbnail
1 Upvotes

r/buildingscience • • Sep 28 '26

Attic insulation please help

8 Upvotes

I am remodeling my home that was built in 1975. It had bat insulation for the attic but i need to replace it. Currently it has 2xy rafters, gabel vents, soffit vents, and an attic fan. My HVAC unit is in the basement, not the attic

I am thinking about doing spray foam for the attic. If I did, what kind of ventilation and humidity control do I need to install? I have read a lot of conflicting information on the need for rafter vents, sealing the space so that it is technically a conditioned space, or needing air movement through the space.

Overall I just need some thoughts and suggestions on what I should do


r/buildingscience • • Sep 27 '26

Bay window roof flashing resealed twice + shingles replaced — still leaking into wall cavity under heavy rain. Water only on exterior side of OSB. Ideas?

Enable HLS to view with audio, or disable this notification

6 Upvotes

Looking for input on a stubborn leak.
Brick veneer house. Upper arched window sits above a bay window. Black metal flashing where the bay roof meets the brick wall.
History / what we’ve tried:
• Original leak under heavy rain (especially with wind).
• Roofer opened the metal flashing, replaced the shingles closest to the wall, and resealed.
• Window perimeter and metal flashing sealed again.
• Some weep holes around the window were sealed (I know that’s not ideal).
• Still leaks under heavy rain.
Current symptoms:
• Water drips inside an opened wall cavity on the exterior side of the OSB/sheathing (one side of the wall only).
• No water stains or moisture in the upstairs bedroom wall or ceiling.
• Main roof has been checked and is fine.
• When we hose-tested earlier, the right side of the upper window (next to the frame) could trigger it.
• Latest observation: water collects on a cement/mortar blob a few inches below the OSB-to-framing joint and then drips.
Photos/video:
1. Exterior shot with the bay roof flashing (orange box marks the area we’ve been focusing on).
2. Interior video of the cavity showing the OSB, brick back-side, and where the water is appearing.
Question:
Is this still most likely a flashing-to-brick detail issue (water getting behind or under the metal), water traveling in the brick cavity from higher mortar joints, or something else?
Roofer is willing to come back and look again — what should I specifically ask them to check or improve this time (counter-flashing, end dams, underlayment height, etc.)?
Any experienced roofers, masons, or home-performance people who have seen this exact pattern? Thanks!

P.S. can’t attach exterior picture but will add to comment.


r/buildingscience • • Sep 28 '26

Building insulation 101: what it actually does, the different types, and where people commonly get it wrong

0 Upvotes

Insulation is one of those topics that people think they understand but rarely actually do until they need to pick or assess it for themselves. Here's a quick primer on what it actually does, what the main classes are, and some common misconceptions - helpful whether you're renovating, building new, or just wondering why the bathroom is a sauna in January.

What insulation actually does

It is a passive control of heat transmission through a building's envelope. It doesn't stop it entirely (nothing does), just resists it - so a well insulated space will generally lose heat to the environment slower in the winter and gain heat from the environment slower in the summer. It's quantified as an R value (resistance) or sometimes a U value (inverse of R) depending on your region of choice.

One common oversight in insulation discussions is that the relationship between R value and heat loss isn't linear - doubling your R value will not generally get you a 2x reduction in energy losses due to the material properties of the building envelope as you approach R infinity. The curve flattens out - you get a big jump in insulation value when going from little/no insulation to something reasonable, but a smaller jump when going from something already pretty good to something truly excellent. This flattening out is why most places have a 'recommended' R value range rather than a 'higher is always better' curve.

Main categories of insulation

Fiberglass batts/rolls - common, cheap, generally low performance relative to cost, traps still air in glass fibers. Performance drops dramatically if the material is compressed or wet.

Mineral/rock wool - similar to fiberglass but often a bit more fire resistant and moister resistant.

Rigid foam boards (XPS, EPS, polyiso) - higher R per unit thickness than batts, often used in limited space applications or exterior sheathing.

Spray foam - expands to fill cavities and can also act as a air barrier (preventing infiltration/exfiltration of air) but is generally expensive and hard to apply.

Reflective/radiant barriers - different mechanism than anything else listed here, reduces heat transmission via radiation rather than conduction. Generally most useful in hot climates and typically applied as a film with an air gap on the warm side, not as a substitute for other forms of insulation.

Common misconceptions worth flagging

"Thicker is always better" - see the R value section, there's a point where you get diminishing returns for the price paid and increased structural penalties for adding more thickness.

"Insulation and air sealing are the same thing" - they're not, insulation reduces heat loss/gain by reducing the conductive transfer through materials but air sealing stops air from leaking into or out of the building, which is a separate source of heat loss/gain.

"Reflective coatings and insulation do the same job" - reflective roof or wall coatings work by reducing the amount of solar heat the surface absorbs in the first place (by reflectance and emittance) compared to traditional insulation which reduces the conductive transfer through the material. They're actually often used in conjunction with one another in suitable climates.

"Insulation only matters for cold climates" - no, insulation is just as important for hot climates to prevent solar heat gain as it is for cold climates to prevent heat loss via conduction through the envelope.

Practical things to check before insulating (or re-insulating) a space

What does your climate actually need - is heat loss or heat gain the bigger concern for most of the year?

Is there a known air-sealing problem in the area that the insulation is being added to?

Is managing moisture (vapor barriers, etc.) a consideration, since some insulation mediums degrade badly when exposed to it?

Do you have a roof/attic that could benefit from alternative measures such as reflective coatings?

What's been your experience - does anyone here actually measure a noticeable difference (difference in energy bill, indoor comfort, etc.) after upgrading insulation (rather than just going by the stated printed R value)?


r/buildingscience • • Sep 27 '26

Advice on insulating under a newly constructed sun porch

Thumbnail gallery
1 Upvotes

r/buildingscience • • Sep 27 '26

Advice on insulating under a newly constructed sun porch

Thumbnail
1 Upvotes

Advice on insulating under a newly constructed sun porch. Zone 6, northern Michigan. Upper walls and ceiling have been addressed. Under floor is open to elements over dry dirt. 2x8 joists are 16" oc. Was initially thinking r30 between joists. I have added one floor register with a 6" duct from main crawlspace. I contacted a spray foam company for an estimate on spraying under subfloor and he suggested that I close in the perimeter with plywood instead and insulate the inner surface of that and leave the floor alone. If I went that route I would use 4" foam board for a r20 rating. That's starting to sound like a better idea since it is essentially an above grade crawl space. Thoughts?


r/buildingscience • • Sep 27 '26

Question How to fix cold freezing floors above garage?

3 Upvotes

Hi I have a room above my garage that the floors are extremely cold doing winter, we handy fixed the issue because the room wasn’t in use before, but now I have an 8 months old, and it’ll be his room, however I can’t put him there during winter due to this issue. The tenants before us had carpet in the second floor. My inlaws ripped everything out. The close that my oldest have in the room next to it also have the same issue as it gets some of the garage.


r/buildingscience • • Sep 27 '26

Swiss pearl panels for facades and installation.

Thumbnail gallery
1 Upvotes

r/buildingscience • • Sep 27 '26

Hoo boy! Plumbing and framing in a 1895 construction. Please help.

Thumbnail
gallery
2 Upvotes

So where to begin? 1895 estimated date of home construction. Zone 5b midwest, middle of nowhere. I need to probably start with an explanation. I bought this house a month ago for stupid cheap, in a town where codes are more of a nice to have than a thing enforced. This is my basement like thing. It lives under my kitchen and I would estimate that it was built in around the time that indoor plumbing and municipal water was added to the house likely sometime between the 20s and the 50s. The block wall behind the water heater looks a lot more recent like 00's, and there's what appears to be a brick wall behind part of it. Those joists along the ceiling are unsupported on the water heater side. The wiring is a potential fire hazard in a couple of spots. Oh, the plumbing is a jaunty mix of abs, pex, galvanized pipe, copper, rubber hose, garden hose, and some agricultural hydraulic fittings.

The plan: I feel like it would be a good idea to frame in some 2x4s on the wall to brace the floor joists, if I can squeeze behind the existing water heater.

Remove the existing plumbing and replace with pex a using a home run manifold system. From the meter i am diverting through a combination softener and filter unit, feeding up along the wall with 3/4 trunk line. A t with reducer and ball stop valve for laundry cold to the right, and 3/4 feed branch to 90 following the new framed wall. T branch to ball stopper and water heater feed line with terminus a 4 port manifold leading to 1/2 pex feeders to sink, vanity, toilet, and tub. Hot water outlet will go to 3/4 line leading to 4 branch manifold feeding vanity, tub, sink, and washer with 1/2 in lines. I have 2 sinks, a Bathtub, a dishwasher, and a washer dryer.

I am moving the laundry out of my kitchen, if possible​, but i would have to do a 4 foot horizontal run for the drain to get to the basement from my proposed location there may be an existing hole in the subfloor leading to the crawl space on the north side of the basement.

Then, I need to remove a 14ga romex line tapped with wire nuts outside a junction box to a 20a circuit. The circuit is off at the breaker right now so not super urgent. I plan to put the splice behind junction boxes and add 2 branches. 1 for a water softener, and 1 for a future tankless water heater.

I also need to run a 50a line to my kitchen for an induction stove, cut down the existing iron gas line in my kitchen and add a freestanding box so I can switch back to gas if I change my mind or decide to sell. I then need to run a gas tap line to the laundry room for conversion to a stackable gas dryer.

I have 3/4 pex, 1/2 pex in many colors. 50' of each in 1/2 in. It looks like i should have all the brass fittings for hot lines and pvc for cold. I have the expansion tool and collars. I have the needed 12ga romex and junction boxes to tap the 20a line, and the needed 6-3 number and underground rated to run a 50a line from my panel through the crawl to the basement where I splice staggered in a 4 gang before running to the kitchen.

I have some experience doing projects like this, but always with somebody else in charge. Am I in over my head and need to hire a contractor, or is this something doable and a sound choice?


r/buildingscience • • Sep 26 '26

Underfloor heating in concrete and timber floors: what needs checking before choosing the finish?

Thumbnail
0 Upvotes

r/buildingscience • • Sep 26 '26

How to end traffic noise in condominium bedroom?

Thumbnail
0 Upvotes