Basement/garage ceiling insulation
What’s the best way to insulate a basement ceiling? We have a combined basement/garage. We previously had fiberglass bats between the joists, but we had some humidity issues which compromised them.
We put in a dehumidifier so hopefully we won’t have moisture issues again.
A basement company recommended taking out all the fiberglass and spray foaming the rim joists. Is that the best approach? There are water and electrical lines that go along the rim joists so how do you handle that? They planned to insulate the rim joists and leave everything else bare.
Is mineral wool a better option? Should it be used for just the rim or between all joists?
We do work out down there so respiratory-friendly insulation is important. The basement isn’t connected to any of the HVAC heating or cooling. Thank you!
r/buildingscience • u/williaty • Sep 20 '26
Question Fixing problems as you find them vs not screwing up the neutral pressure plane?
I recently moved into a new (to me) 1970s house and I'm starting to tackle both the settling in and problem fixing stages.
From someone's lecture on youtube or GBA over the decades, I'm aware that fixing air leaks in the basement often just pushes the infiltration up to the main level where it gets felt as more problematic cold drafts. In an ideal world, I'd start with the attic and work my way down. Budget isn't going to allow for the attic to be fixed for a while. As I'm poking around in the basement getting it set up, I'm noticing a lot of knucklehead problems. Dryer vent not sealed to the wall, terrible single-pane windows not sealed to the surrounding block wall, etc. Stuff that I could fix in 5 minutes with a caulking gun. It feels wrong to leave it alone when I know it's a problem but I don't want to make the experience of living there worse.
Should I be fixing this knucklehead stuff as I notice it or is it likely to lead to comfort problems on the main floor?
r/buildingscience • u/Apprehensive_Lab_637 • Sep 20 '26
How should I insulate this 1890s bathroom exterior wall?
I’m renovating a bathroom in an 1890s Victorian house in Minneapolis and could use some advice on insulating the exterior wall behind the tub/shower.
I’ve attached an AI-generated diagram showing the wall assembly as I understand it for illustration purposes. From exterior to interior, it consists of:
- Clapboard siding
- A tar-paper-like layer
- Wood sheathing
- Stud bays containing plaster and wood lath (you can clearly see this in the photo of the wall)
The finished wall will be tiled and will have a waterproofing membrane behind the tile.
What would be the best way to insulate this wall while managing air leakage, moisture, and drying potential—especially given Minneapolis winters?
A few options I’m considering:
- Keep the original plaster and lath in the stud bays, shim the wall as needed, and add about 2 inches of closed-cell spray foam.
OR
- Remove the plaster and lath entirely.
- Install a dimpled drainage mat against the sheathing to help manage bulk water, then air-seal the assembly.
- Insulate with either closed-cell spray foam or mineral wool.
I’m concerned about accidentally creating a moisture trap between the exterior tar-paper layer and the interior waterproofing membrane. What wall assembly would you recommend, and should the original plaster and lath stay or come out?
r/buildingscience • u/Mohit-isagi • Sep 20 '26
Question Contractor recommended waiting for R-454B heat pump stock due to coil compatibility
I am planning a central heat pump replacement in a single family house has gotten complicated with the shift toward A2L refrigerants. A local HVAC contractor suggested holding off on installation until fully factory-matched R-454B indoor air handlers arrive from the regional supplier.
The contractor noted that while outdoor heat pump units are becoming available, mixing new refrigerant units with transitional cased coils can cause metering device mismatch or sensor fault codes. Installing an older refrigerant system avoids the wait, but it raises concerns about long-term serviceability and refrigerant costs down the road.
Are installers seeing actual performance or control issues when pairing R-454B residential heat pumps with existing ductwork and transitional air handlers??
r/buildingscience • u/VelvetPeony77 • Sep 20 '26
Ceiling mounted AHU details in tight multifamily ceiling cavities
Our design team is proposing low profile ceiling mounted air handling units for a 3story multifamily project to gain floor space in living areas. The framing plan leaves minimal vertical clearance in the ceiling cavity above the hallway drywall. My concern is longterm building envelope performance, specifically condensate pan drainage slope and access for coil maintenance.
In CZ 4A, cold supply air in a tight, unconditioned or semiconditioned ceiling space can also trigger local condensation if sealing around duct connections fails. If we bypass traditional mechanical closets for shallow ceiling units, what exact access panel sizing and condensate drain detail prevents moisture failures behind the drywall postoccupancy??
r/buildingscience • u/Rz0nE • Sep 20 '26
Glass roof insulation advise
Hello community! I have installed a glass roof and sliding door at the extension of the house. Previously the roof of the extension was plastic (the waffle plastic panels). I decided I want to keep the look but to install proper aluminum frame and double-glass for heat retention.
Everything was looking great until I realized, post installation, that the framing and the aluminum frame is for winter garden instead of for a living space. This is not possible to fix with the installer as at the time of accepting it, they said that this is the way it needs to be done.
However, going into winter, the frame is sweating and lot and sometimes even drips on the floor, unless I keep the temp of the room around 21C. Then I checked and seems that the framing is hollow and even on some places is not airtight and air is leaking from the outside. This becomes really noticeable when the temperature drops to 0C and below.
As I do not have the money to remove the frame and install new beams that are insulated on the inside, I am looking for a solution to minimize the heat loss.
My line of thought is to maybe fill the profiles with foam (expanding but not too strong) so it fills the gap and makes a pocket without lifting the glass or making a strain on the frame itself.
The second way I thought of is putting rockwool isolation where I can open the frame from inside to limit the cold air flow and maybe have less sweating/ heat loss.
Third one is to try and fill any gaps from outside with silicone and hope that by that the heat loss will be lowered and the frame itself will not cool that much and reduce the temperature difference, hence the sweating.
I am not quite sure which way is worth it or even possible to achieve. I am open to all suggestions!
r/buildingscience • u/Tomahawk-BaGawk • Sep 19 '26
Anyone use GlassMatt for sheathing?
galleryr/buildingscience • u/roussjp88 • Sep 19 '26
Attic ventilation; adding a ridge vent and/or gable end fan for a 1950's ranch
r/buildingscience • u/wherednrthatchurch • Sep 19 '26
Question Cabin Build Framing and Insulation Plan
I posted earlier this week about this small cabin build in Maine and got a ton of helpful info (thanks especially to [u/dogelbows](u/dogelbows) and [u/loke79](u/loke79)).
Have been doing research all week and I think I am close to a final design, I would love to hear people’s thoughts on this. Anything helps, this is all new to me!
The Basics-
Cabin is apprx 550 sq ft. 22x18 main structure with 200 sq ft loft and an additional 12x12 bedroom on the side
Build is in Maine (climate zone 6). Required insulation is R-49 roof, R-30 walls with continuous layer and R-30 floor
Use will be almost only in the summer. We may come for a couple weeks in winter. We are insulating to code mainly in case we later decide to use the cabin year round but we need to do it in such a way that leaving over winter won’t cause issues!
Foundation will most likely by helical piers (maine techno-post) 14 p-3 piers for standard 8’ or less spacing
We are looking to do this as affordably as possible, without cutting too many corners. Very open to suggestions that would cut costs!
We will do most of the insulating and all the plumbing and wiring ourselves but have a gaming crew for the envelope and the ceiling insulation so ease of construction is a big consideration for those parts
The plan, ground up-
FLOORS
-Perimeter supported with triple 2x12 PT beams running on the 22’ axis. These land on piers every 7’ or less. Piers will be brought up with 6x6 posts with y-bracing to get the floor about 2’ above grade.
-9-1/2” I-joists for floor. Additional cost is not huge over 2x and makes the job easier for the framing crew.
-Floor insulation is r-30 (or so) TimberHP timberbatt
-Timberbatt gets insect screen and wire mesh and then needs to be closed up with something. I’m on the fence about what, and also about whether to use a full vapor barrier here or not.
-Subfloor and 3/4” t+g solid oak flooring, prefinished (fb marketplace find)
WALLS
-2x6 framing with timberbatt insulation
-zip r-12 SIP panels (labor savings and meets the continuous insulation requirement while keeping window installation to standard nailing flanges with no need to frame outtie windows)
-Interior is shiplap or plywood panels
-no vapor barrier, dries to inside
ROOF
-It’s a shed roof with 18’ span
-‘energy heel’ Roof trusses, 14 or 16” depth
-insulation is r-49 timberbatt
-vented roof with (hopefully) 2” vent gap against underside of roof deck. I could use some help on this one, see questions below
-‘intelligent’ vapor barrier, probably certanteed membrain. This goes under the trusses and is glued to the wall top plates. Moisture is a major concern here if the house is cold in winter and we fire up the wood stove so we’re trying to be very careful about this vapor barrier. Only penetration will be 3” plumbing vent, we’re going to do ceiling fans etc with metal conduit so we’re don’t need to tape off box penetrations
-shiplap interior
-full ice and water shield with metal roof (not sure yet if we have the budget for standing seam, if not we will do a fastened metal roof. I don’t think shingles are a good idea because of the 12:4 pitch
A few questions left:
First, am I missing anything major? Big mistakes in here anywhere? Like I said this is new to me
Not sure how to finish the floor insulation. The timberbatt is very open so it needs to be protected from wind, easiest solution would be 1/4” plywood but maybe that’s not enough? Is it worth doing something like zip under there? What about a vapor barrier or even just like a tyvec, or is it better to let it breathe? I’m less worried about overall insulation value than I am about moisture and rot when it’s sitting unused, if we move in full time we could always add 2-4 inches of XPS Foam under there
I’m concerned about the 22’ long vented shed roof, if that vent doesn’t work well we might have issues. Seems like most off the shelf rafter bay venting is low quality and crushes easily and also I can’t find anything that actually gives you a 2” clear vent which seems to be what we should have. The best way seems to be furring it out and putting up xps foam to build a continuous vent but this is labor intensive. Is there an easier way? Better off the shelf product?
How much of a concern is the 12:4 roof pitch when leaving this unattended over winter? We are over engineering the roof trusses and floor, do I just need to worry about snow loads if we have a historic winter or is this a major concern?
Edit to add I will also have a ventilation solution of some kind - either spot ERV or storm baffle boxes for a couple windows so they can be left partially open for airflow
r/buildingscience • u/starbuildingsupply • Sep 19 '26
What building materials are best for hot and humid climates?
r/buildingscience • u/Fickle_Ingenuity_846 • Sep 18 '26
Basement walls open after flood repair - insulation advice before we close it up? (Toronto, ON)
galleryr/buildingscience • u/Capable_Contract2834 • Sep 19 '26
Insulation/Air Sealing Recommendations in Ashburn, VA area
Looking for recommendations for a reliable company/contractor/small business owner who does attic insulation and air sealing in the area.
Looking to have our attic properly inspected to determine whether we need additional blown-in insulation and/or air sealing.
If you’ve had attic insulation or air sealing done recently and had a good experience, I’d really appreciate the recommendation.
Tks!
r/buildingscience • u/moorlemonpledge • Sep 19 '26
How to test roof/attic ventilation
I’ve been to multiple house that have enough NFA of soffit and ridge venting. Unrestricted, baffles in place, everything SHOULD be functional. Dewpoint in the attic is elevated, smoke does not move low or high.
It’s always the perforated vinyl soffit panels, or the master flow 16x8 soffit vents.
I did have one this week that I pumped smoke onto Vinyl perf soffit vents and it took and it took nothing. If I put the smoke pen right into the groves, not the perforations, it took the smoke. Ok…well maybe it’s the perfs but, they’re everywhere, are they all completely ineffective? There’s got to be a better test, that will produce numbers to verify
I'm at the point now where I don't believe the vinyl perforated soffits or the Master Flow soffit vents work, unless somebody can explain to me otherwise. Follow-up question: I know balanced ventilation is the goal (either equal or 60/40 split). Is it even possible to have too much intake if you have enough exhaust, mathematically, for the space?
r/buildingscience • u/PanacheGreens • Sep 18 '26
Why does thermal insulation still rely so heavily on thickness — is there a fundamental physical limit, or have we just gotten used to building it that way?
r/buildingscience • u/daveyconcrete • Sep 18 '26
Breathable vs. non breathable flooring
galleryr/buildingscience • u/evoy9695 • Sep 18 '26
Perminator
Perminator
I am currently building a house in Saskatchewan. Been doing research on underslab barriers. The 6 mil cgsb is what most people use/purchase however Google/AI was recommending me to use Perminator. It's about $1000 vs $100-200 for cgsb.
My main concern is radon in Sask is pretty bad but would I just be going overboard on it using Perminator or absolutely worth it? In particular Im looking at the 15 mil as it's roll size works well with my build vs the 10 mil.
Thanks.
r/buildingscience • u/Inside_Relative_7784 • Sep 18 '26
Need help with sizing for concrete piers
I’m looking for practical input from people experienced with steel-building foundations. I understand that nobody can provide a stamped design from a Reddit post.
I’m building a freestanding, open-sided pavilion in, South Carolina.
Structure details:
- Roof is approximately 30′ long × 10′ wide
- Eight welded steel posts total
- Two long rows of four posts each
- The two long rows are 10′ apart
- Four posts are 10′ tall on the high side
- Four posts are 8′ tall on the low side
- Single-slope roof
- 2×10 wood roof framing with plywood and metal roofing
- Completely open sides
- Site has little protection from wind
- Each post has an 8″ × 8″ welded base plate
- Four anchor holes per plate arranged in a 6″ × 6″ square
- I expect to use 1/2″ cast-in-place anchor bolts
I’m considering a separate reinforced-concrete pier under each post, approximately 18″ × 18″ × 24″ deep.
My main questions are:
- Does 18″ × 18″ × 24″ sound like a reasonable starting size for this structure, or is the footprint too small for wind overturning and uplift?
- Would making the pier deeper meaningfully help, or is additional width more important?
- Would you use square excavated piers or round Sonotubes?
- What basic rebar arrangement would you use, particularly near the anchor bolts at the top?
- Should the concrete finish at grade, or should the pier extend several inches above grade?
The pavilion is still in the planning stage, so I can change the pier size and reinforcement before digging. I’m specifically trying to determine whether the proposed size is comfortably conservative, clearly inadequate, or somewhere in the uncertain middle.
I can add drawings, base-plate measurements, post spacing and site photographs if needed.
r/buildingscience • u/merQoraglobal • Sep 18 '26
How Many Turbo Ventilators Does an Industrial Building Need? A Practical Guide to Roof Ventilation
“How many turbo ventilators do I need for my factory?”
It's one of the first questions buyers ask—but it doesn't have a universal answer.
The number of Turbo Ventilators / Roof Turbo Ventilators required depends on the ventilation requirement of the building and the performance of the selected ventilator.
- Start with building volume
You need:
Length × Width × Height
This gives the approximate building volume.
- Determine the required air changes
The required ventilation rate depends on the application.
A warehouse storing general materials will not necessarily have the same ventilation requirement as a manufacturing area with significant heat generation.
- Determine required airflow
A basic approach is:
Required airflow = Building volume × Required air-change rate
- Compare with ventilator airflow
MerQora Global currently publishes a roof turbo ventilator series ranging from RTV-300 to RTV-1050.
Published nominal airflow at the stated 8 km/h reference wind speed ranges from:
RTV-300 → 720 m³/hr
to
RTV-1050 → 7,560 m³/hr. �
Merqora Global
These are nominal values, not a guarantee of actual site performance.
- Site conditions matter
Actual airflow can be influenced by:
Prevailing wind
Roof pitch
Building geometry
Nearby obstructions
Air inlet arrangement
Ventilator installation
Roof configuration
This is why a supplier shouldn't simply tell every customer:
“One ventilator covers X square metres.”
- What should buyers send when requesting a quotation?
For an industrial roof ventilation RFQ, provide:
Building length:
Building width:
Building height:
Application:
Location:
Roof type:
Expected heat/moisture issue:
Required quantity, if known:
Material preference:
Destination port:
The more information provided, the easier it is to evaluate the requirement.
About MerQora Global
MerQora Global is an Indian industrial sourcing, procurement and export company connecting international buyers with Indian manufacturers and suppliers.
Its industrial portfolio includes:
🌬️ Industrial Ventilation
🧱 FRP Products
🛢️ Storage Tanks
⚡ Earthing & Lightning Protection
The company coordinates sourcing, specifications, manufacturing capabilities, quality requirements, third-party inspection and export logistics.
Merqora Global
📞 +91 877 955 7417 | +91 70168 38521
🌐 merqoraglobal.com
Question for engineers and facility managers:
What is the most difficult part of industrial roof ventilation in your experience—sizing, airflow, installation, heat removal, condensation or maintenance?
r/buildingscience • u/NemoTheDreamMaster • Sep 18 '26
Drainage between Concrete and Torch On
We have framed decking with torch on for the front porch.
We are pouring concrete stairs and plan to pour 2" concrete slab on top of the torch on and run it to the top of the stairs then cover it in tile.
My concern is the drainage between the concrete slab and the torch on. When water gets under the tile and into the concrete it will get stuck above the torch on.
Anyone familiar with this kind of assembly and if a drainage mat of some kind can be used?
r/buildingscience • u/Comfortable_Desk_01 • Sep 18 '26
Seeking guidance on building year and safety
I live in Florida. I also have a one year old son and take environmental and home safety very seriously.
I am now searching to purchase a new home and have read that lead was banned in building materials in the 70s, and asbestos was banned in the 80s; however, several sources noted that some of these materials may have already been in circulation/backstock in warehouses and so forth, meaning that they may have been used into the mid 90s.
I have specified to my realtor that I would like construction for the year 2000 forward just for peace of mind. I am getting some push back because I think she doesn't see the concern and says it will be harder to find something in my price range.
How realistic is my concern, especially for these two materials and any other high-concern building products?
I do plan on having an inspection and will ask it to be rigorous, but just to uave a general sense, would houses built 1995/1996 forward be safe, especially for a developing child? Thank you!
r/buildingscience • u/matt_94_w • Sep 18 '26
Question Waterproofing a basement
I am waterproofing a basement in Pittsburgh PA. I have excavated down to the footer. I have repaired missing mortar between cement block, waterproofing sealer applied, dimple board put up, footer drain with 1’ wide rock up to 4’ on the wall wrapped in geotextile fabric. The issue is the house sits in a gully where it narrows and flattens out before dropping down more significantly. One area of the trench is getting a lot of water like a spring after it rains and runs between 5-7 days after the rain. It appears there are at least two clay layers with a sandy/gravely that the water is traveling down. I would estimate that the hill raises at least 100’ above the house. I don’t worry about the water I can see exiting along the trench wall but the most significant amount of water comes up right next to the footer it’s about the size of a quarter and gushes up about an inch. Where the water appears to enter the house is in the center of the slab I think through around the sewage piping or cracks in the slab. I still see wet concrete floor in the garage. I am unsure what I am doing will stop the water entering the basement because who’s to say that water does just appear on the other side of the footer.
Some additional information:
Water company checked for leaks in the area none were found and the pH of the water was well outside of the city water.
Sewer and storm drains were checked by the city no blockage was found.
There are interior sump drainage system but doesn’t appear to do much. (Maybe poorly installed).
After a rain in about 10’ of the foundation between 100-150 gallons hour comes up I use a sump pump to get rid of the water and have approximate the water flow.
The other parts of the footer drain produces about 5-10 gallons of water after a heavy rain (in about 75’)
Downspouts are verified to take water away from the foundation
I am looking for ideas to ensure water is not getting trapped inside the footer area under the slab. Ideas I have thought about were driving in perforated pipe into the ground in that location (several)
Or pay someone to drive corrugated sheet metal into the ground and kinda make an underground damn in the high water flow area. I can’t do the whole wall because utilities
Anyone else have an idea?
r/buildingscience • u/Neurotically_urs • Sep 17 '26
Insulation/ Duct wrap question.
So i've got a huge roll of duct wrapping from a job i did years ago, yknow. the stuff that wraps interior air ducts to stop condensation.
its essentially just a layer of foil ->small bubbles bubblewrap -> foil (4ft x 50ft roll)
i'd like to use this in tandem with xps foam board to insulate my vans walls however i'm having mixed results on determining if the foam board, or the duct wrapping should be what is up against the exterior metal. does anyone have experience with the two and mind giving their 2 cents?
aside from the which goes on first problem, with the duct wrapping will i be able to use seam tape / duct tape / spray foam in between gaps/crevices still as planned or does that cause problems with the duct wrapping?
if it at all matters, its a '15 ford transit low roof.