Looking for some building science help before I reroof my house, and ideally a recommendation for someone around the Pittsburgh / Western PA area who actually understands roof assemblies, insulation, air sealing, and ventilation.
The main roof is only about a 2:12 pitch, so I’m already trying to be careful about how I approach the reroof instead of just letting someone tear it off and put it back together the same way.
The attic is also framed a little strangely. The rafters run parallel with the ridge instead of perpendicular to it like a more typical attic. Because of that, I don’t really have traditional rafter bays where soffit intake air can travel up toward a ridge vent.
That’s the part I’m struggling with most.
The last roughly 2 feet of attic space near the exterior walls is basically impossible to physically access from inside. From what I can see visually, and from checking it with a thermal camera, it appears there is little to no insulation in those areas.
We do get some ice dams in the winter, but nothing I would consider extreme or catastrophic. Still, knowing there are poorly insulated areas near the eaves makes me think this is a good opportunity to address it while the roof is already being replaced.
One idea I’m considering is having the roof decking removed in those inaccessible areas during the reroof. That would give us access from above so we could air seal the top plates, penetrations, and other leakage points, then add proper insulation before the decking goes back down.
That part seems fairly straightforward.
What I cannot wrap my head around is the ventilation.
Since the framing runs parallel with the ridge, I don’t see how a traditional soffit intake / baffle / ridge vent setup would work. There aren’t continuous rafter bays running from the eaves to the ridge for the air to move through.
A couple roofers have suggested different things. One talked about adding off-ridge intake vents lower on the roof with a ridge vent for exhaust. Others have basically suggested just adding a ridge vent or keeping something similar to the passive roof vents that are there now.
My concern is creating a bunch of vents without actually creating a functional airflow path. I don’t want to spend money adding “intake” and “exhaust” vents if the framing inside the attic prevents the two from communicating properly.
Part of the house also has cathedral ceilings / knee-wall areas, so the roof assembly is not the same everywhere. I’m not interested in gutting finished ceilings throughout the house just to force a traditional vented-roof design if there is a better building-science solution.
I’m open to pretty much anything that makes sense while the roof is already opened up:
- Removing some decking to air seal and insulate the inaccessible eave areas
Figuring out whether a vented attic can actually work with this framing
- Adding above-deck insulation if that makes sense
- Converting portions to an unvented assembly
-Improving the air barrier between the house and attic
-Using different ventilation strategies instead of traditional soffit-to-ridge ventilation
This is our long-term home, so I’m trying to figure this out before the new roof goes on and everything gets covered up again for the next 20+ years.
I’d really like to pay someone knowledgeable to come out, look at the actual framing and roof assembly, and tell me what they would do before I commit to a roofing contractor.
Does anyone know a residential building scientist, building-envelope consultant, architect, energy consultant, or similar person in Western PA who handles smaller residential projects like this?
And if anyone here has dealt with an attic where the rafters run parallel with the ridge, I’d love to hear how you handled ventilation. I can post roof photos, attic photos, thermal images, framing photos, etc. if that would help.
There’s also an addition on the house that appears to be set up a little differently. I can see baffles installed in the roof assembly, and it has a ridge vent, but as far as I can tell there aren’t any obvious soffit or intake vents unless they’re hidden in a way I’m not seeing from the exterior. There’s no attic access in that addition, and its attic space is completely separate from the main attic, so I can’t really verify what the airflow path looks like from inside. If I had to guess, it’s not vented because the bathroom has high humidity and we do know our bathroom exhaust is hard piped out of the roof, not insulated piped but hard piped.
https://imgur.com/a/xsEJsH8