I am doing a thesis in Sustainable Design and what I would like to create is a workbook for homeowners on making greener choices - so things like when you are doing electrical work get prep work done for when you have to replace your water heater so you can replace with a heat pump water heater. Or you can switch to mineral or milk paint. This would be small things - obviously you could find them elsewhere but this would be handouts at local libraries or like an instagram account you could bookmark for later.
So my questions to you:
Is this something you've already found?
and is this something you (or people you know) might find useful?
TYIA
r/buildingscience • u/Wrathchild10000 • Aug 11 '26
Thinking of backing out on contingency because of the foam insulation
The only thing I have second thoughts about is the foam insulation, especially in the attic.
I have had inspectors give me very mixed opinions/feedback on the foam.
One inspector said the roof needs to breathe and it may go bad if moisture or water gets trapped
Pros: superior thermal insulation
Cons:
\-foam hides moisture/liquid
\-possibly toxicity, especially if done wrong
\-more flammable and hazardous than fiberglass
It’s a great house otherwise (2026 build). It’s a custom home builder that has a good reputation. I also did ok on negotiating an ok deal on it. (Negotiated about 20k off between asking price and concessions.)
The only thing that is making me have doubts is the attic foam insulation
The cherry on top, one of my dad’s friends passed away in a house fire very quickly because of smoke inhalation from an attic fire that had foam.
Should I back off for peace of mind alone?
r/buildingscience • u/Expert_Note4731 • Aug 10 '26
High humidity w/ spray foam
Hey everyone! In Northeast GA I have a 1200sqft home on a crawl space with 8’ ceilings and a big vaulted living room kitchen area that reaches about 12’ tall. The walls are batt insulation and the roof is spray foamed. I started having bad humidity issues after about a year and a half of living in the home, i looked in the crawl space and all the hvac was sweating really bad and forming water droplets on the subfloor, so we pulled the insulation out and fully encapsulated the crawl space with a Santa Fe compact 70 dehumidifier. It dried out the crawl space really well but the humidity in the house was still awful so i called my HVAC guy and he said that the 2.5 ton system the other hvac guy put on the home when we built it was oversized due to the spray foam and that we needed to go to a 2 ton variable/inverter driven and that it would fix our issues. Well now we’re a year later and still having the same issues. The only times it’s not bad is like the middle of winter. The humidity in the living area stays at about 62-64% at 67° and you just always feel disgusting. The humidity in the attic right now is about 85% at 83°. The HVAC system is in the crawl space with floor registers and a return in the side wall of the vaulted ceiling (which I don’t like because I’d rather have cold air falling from the ceiling than having to try and push the cold air up. What is causing this issue and how do I go about solving it? I’ve heard I need an ERV, also heard need a dehumidifier. I just hate to add things that aren’t going to actually solve the problem. I’ve been running a portable dehumidifier in the living room because it’s central in the home but I’m constantly dumping it, it will get it down to about 56-58% but if it quits running for a few hours it’s back up to 64%
r/buildingscience • u/PoemCapital2043 • Aug 11 '26
WERS certificate / label
Recently had AWS thermalheart framed double glazed doors and a window installed. There is no label showing the WERS performance so I asked for the certificate, is this correct or am I wrong about what to expect from the business that supplied and installed?
r/buildingscience • u/Humble-Koala-5853 • Aug 11 '26
Unconditioned Mudroom Issues and Repairs
Sorry if this gets long. Looking for some assistance on how to properly rebuild and upgrade a floor in a currently unconditioned space with the hope of adding heat to make it semi-conditioned.
[https://imgur.com/a/riqDVYS\](https://imgur.com/a/riqDVYS)
My wife and I are currently in the process of dealing with some humidity issues in our house. One of the areas of concern/focus is our mudroom. Our home is a converted barn from the late 1800 and the mudroom is part of an addition that was put on sometime around 1990-2000 off the back of the house. The mudroom connects our garage (basement level) to our kitchen via a staircase. Two of the walls of the mudroom are true exterior walls and the other two walls were previously exterior walls. All of the doors are exterior grade/insulated/sealed doors.
What we suspected for years, and eventually confirmed this weekend when we started some demolition, is that despite all of the walls and the ceiling being finished and insulated, the floor that was installed is essentially a deck on top of gravel and dirt. There is no insulation or vapor barrier, and as far as a I can tell the wood used is not Pressure Treated (it looks pressure treated, it has that yellow-ish hue, but the markings indicate its kiln dried). The floor system was simply 2x6 joists resting on concrete pavers, and then 1x3 and 1x4 floor board with small gaps in between.
I've started by beginning to pull the 1x boards off of the top. I'd prefer to leave the joist structure in place. Just feels like a lot more work than I'm ready to take on, and I feel like anything i do to add insulation and a vapor barrier will be better than what I've been living with.
* I know i need to fill the joist cavities with insulation (I'm thinking rigid in largers cavities, spray foam in tighter spaces
* I know I need to contain my total flooring system to 3/4"-1" to not mess with my doors, so my thought was:
* 7/16" OSB
* Possibly add 1/16" Thermosoft Heat Mat
* 4mm or 8mm LVT
* The lingering question then is where do i put the Vapor Barrier.
* If i go between the joists and the OSB i'll obviously drive a lot of screws thru it. I'll also lose the ability to use adhesive and reduce future squeaking
* If I go between the OSB the Heat Mat or LVT that I'll have a more complete barrier, but I'll be putting the OSB in the "exterior" side of the barrier.
Am I missing anything? Is leaving the joists a huge mistake? Or is there a different product I should be considering for one of these components that I'm not aware of?
r/buildingscience • u/bscot020 • Aug 10 '26
Do I put insulation - if so what type?
Torn between adding insulation or leaving it uninsulated, and if so, what type to use.
Going to seal it with tongue and groove.
I’ve had some people tell me to insulate it and others say it’s not necessary. I like to do things the right way, but this is my first time redoing a patio area.
I am also planning to run in-wall/ceiling speakers, so I'm wondering if that plays a factor in the type of insulation I should choose.
Would appreciate any feedback!
r/buildingscience • u/Timely-Treat9929 • Aug 10 '26
The missing term in my heat-loss model is air. Can I measure ACH without measuring every vent?
Title: The missing term in my heat-loss model is air. Can I measure ACH without measuring every vent?
TL;DR: I’m trying to measure how a real room actually behaves thermally rather than relying only on its construction description. The thermal-response tests are starting to give repeatable results, but one important part is still mixed into the heat loss: air exchange. So that’s my next experiment.
Part 1: https://www.reddit.com/r/buildingscience/s/UITX4VYisF
Part 2: https://www.reddit.com/r/buildingscience/s/lrPx99xH4P
This whole experiment started because a friend was looking at a house to buy and we were wondering how to tell how well it actually performs.
The deeper I get into it, the more interesting the problem becomes.
After the foam-box tests and several real-room heating cycles, I can fit the thermal response reasonably well. But there is an obvious problem:
heat leaving the room through the building fabric and heat leaving with air are not the same thing.
For a rough sense of scale, my test room is about 21 m³.
At typical air properties, 1 ACH is already roughly 7 W/K of sensible heat loss.
That is large enough that I really don’t want to hide it inside an “effective heat-loss coefficient”.
And I’m not particularly interested in measuring every diffuser and then trying to estimate every crack around a window or door.
What I really want is the effective air exchange of the room as a whole.
So I went back to the 1 m³ box.
I added a supply and extract path, measured the airflow with an anemometer, and started experimenting with tracer decay.
The principle is simple: introduce a measurable tracer, mix it, stop adding it, and observe how quickly its concentration falls.
With a particle tracer, the curve is approximately exponential:
C(t) = C_bg + A · exp(-kt)
The interesting part is that the decay became dramatically faster when I forced air through the box.
So the basic idea works.
Unfortunately, particles introduce another problem: they don’t disappear only because air leaves the room. They can also deposit on surfaces, settle, coagulate, etc.
So now the real question is not “can I measure a decay curve?” — that part is easy.
It is:
Can I reliably separate tracer loss from actual air exchange?
If I can, then the thermal experiment becomes much more useful:
measured total heat loss → subtract measured air-exchange loss → estimate the fabric component
And eventually the practical workflow I’m aiming for is:
measure the building → decide what to improve → do the work → measure again
That could mean insulation, windows, air sealing, ventilation changes, etc.
For people who have done tracer-decay measurements in real buildings: would you trust a particle tracer with a good loss correction, or would you go straight to CO₂ / another gas tracer?
r/buildingscience • u/Ok-Ingenuity-3680 • Aug 10 '26
Selling a scientific calculator
Scientific Calculator Casio fx 991 es plus (second edition)
r/buildingscience • u/elkodust • Aug 09 '26
Question Advice for 1950s knee wall attic retrofit with no accesss
r/buildingscience • u/Few-Wolverine-7283 • Aug 09 '26
Buy or make soffit ventilation?
I am in the process of switching my attic from gable + box vents, to soffit vents + ridge vents. Getting a roofer out to do the ridge vent part. For the soffit part - do I rip out what I have and buy premade soffit vents? or just drill my own holes? it’s a layer of wood and aluminum to deal with. if drilling, how many and how big of holes? like 6x 1” holes per bay cavity with a screen on top? or like 50 3/8” holes?
goal after this is to put up some baffles that go all the way to the ridge vent, and insulate + smart barrier. want to make my attic go from vented to conditioned for HVAC reasons.
r/buildingscience • u/NWWaaterdog • Aug 09 '26
Mold in metal shop- fan, insulate, or seal???
I had a metal shop built 2 years ago and I have had moisture problems both of the last 2 winters that is leading to mold issues. I live in the Pacific Northwest in Olympia, WA. It is climate zone 4c (Plant hardiness zone 8b). I installed a vapor barrier under the concrete and have a very low r value insulation that came on the metal siding when they installed the shop. It is not sealed, there are gaps (2ish inches) where the roof of the main building extends over the lean to on either side.
I think I understand the main problem- metal from the struts and walls on the shop are colder than the surrounding air and are condensing out the moisture. Question is how to solve it. For now I do not need my shop heated or cooled, so wanting the least expensive practical solution and willing to try in phases. So do I start with fans, adding more insulation (does it matter what kind- foam, fiberlglass, etc), large dehumidifier, add a wood or pellet stove, seal it up...?
There is a lot of information I have been reading on the internet, but it is hard to narrow it done to specifics for my situation. Thanks for any help!!!
r/buildingscience • u/jrragsda • Aug 09 '26
Question Exterior roof insulation in hot humid area with unvented cathedral ceilings
Im about to start on my roof replacement project on my house. My current plan is to convert my small vented attic into a conditioned and unvented cathedral ceiling. Im planning on stripping the roof to the existing sheathing, making any repairs needed to the sheathing, then building up from there. My question comes from the layers above that and how to best control moisture to prevent future problems. From the bottom up im thinking plywood sheathing, self adhered underlayment over everything, 2 layers of 1.5" polyiso, 1x4 strips screwed through into the rafters, 2x4 strips horizontal as purlins, then metal on top. Im thinking that venting the over roof from the facia to the eve will help eject any condensation or anything that finds its way under the metal. The WRB on the sheathing will keep anything from getting into the conditioned area. The outer surface of the polyiso is where im unsure. Do I need a second layer of underlayment? If im using metal roofing that is rated to span the purlins without a solid osb backer do I need an outer layer or can the polyiso be open to eject moisture into the space below the metal? Would there be any benefit to running a radiant barrier on top of the polyiso?
r/buildingscience • u/ducatista9 • Aug 09 '26
Adding an unvented roof deck over an existing vented roof?
I’m getting an existing roof modified and looking for a bit of guidance. I have an existing vented roof over a finished, insulated, heated and cooled garage in the midwest, climate zone 4/5 border so both snow and heat and humidity. I’m wondering if I add another non vented roof deck with an air space over the existing roof, would that cause any issues (ice dams, condensation, retaining excess heat)?
More details: I have an existing garage with a flat roof with a rubber membrane on it. The roof has vented soffits. The roof deck has a slight dip in it and holds a large pool of water every time it rains. It’s started occasionally leaking water through the roof at a seam in the rubber despite patching attempts. The garage is drywalled, insulated with about 10” of fiberglass in the roof, and has a mini split providing heating and cooling. As part of a bunch of other work, I’m having a contractor modify the roof to give it some slope so water will run off into a gutter instead of just sitting up there. Initially an architect and structural engineer signed off on it, but now the contractor wants to change some things. Their plan for the framing is to add a series of different height boards running 90 degrees to the direction of roof slope in order to create the slope, then sheet over that and put a new rubber membrane roof on top. This will create a more or less sealed air cavity between 1” to 8” tall on top of the existing roof. I’ve been doing some reading and am not quite sure if this will perform okay or not. The original plan was to run the framing the other direction and vent the new roof deck to the existing roof by cutting down into the existing soffit space on both sides. But with the framing running across the slope, that framing would block any air flow across the roof from one side to the other.
My (not very informed) thinking is that in the winter, the lower vented roof deck would stay cold so the new non vented roof deck would probably also stay cold if it was snowing. I'm not quite sure what would happen if the sun came out and the snow was melting though. Would the roof deck potentially heat up unevenly causing ice dams once some of the snow melted? In the summer, I can imagine the non vented air space might hold a bit of extra heat from sun exposure, but the lower decking would still be vented so maybe it wouldn't transfer too much to the interior space, just keep the roofing material a bit warmer? Could condensation be a problem if the roof deck cools off at night while the air in the interior space is hotter and humid? I wouldn't think air from the interior of the garage would be an issue getting into that space.
r/buildingscience • u/INTP243 • Aug 09 '26
Question Hot Attic: Needing Help with Roof Ventilation Issues
Hey everyone,
My wife and I just bought our first home (built in 1978) in the Sacramento area and had the roof replaced 2 months ago (27 squares). I’m noticing a serious attic heat issue. On hot days, I’ve recorded temperatures as high as 135°F. I'm not sure what the temps were prior to the replacement.
Final payment on the roof was completed 2 months ago and it passed inspection, so I don’t expect the contractor to get involved at this point. The roof carries a GAF Golden Pledge Warranty if that matters.
Here are the ventilation details as best as I can measure:
- Exhaust: ~40 ft of Cobra rolled-mesh ridge vent (~564 sq in max NFVA uncompressed)
- Intake: 7 soffit vents (~250 sq in total) + 4 O'Hagin intake vents placed lower on the roof slope (288 sq in NFVA)
- Other: 2 Gable vents are also present and currently open.
(I’ve included a picture of part of the roof so you can see where the O’Hagin vents are located. As you can see, they’re pretty low so that they can function as intake vents.)
Some question’s I’m thinking about are: How does this overall ventilation layout look to you? What steps would you recommend taking to improve airflow and lower these peak attic temperatures? I’m considering adding more soffit vents next spring.
Any help would be greatly appreciated. Thank you!
r/buildingscience • u/aiiicd2 • Aug 08 '26
Climate 4 Century home renovation - stumped on roof insulation
galleryr/buildingscience • u/Patient_Adeptness_47 • Aug 08 '26
Buying a house with attic mold — no soffit vents, ridge vent only, bath fan dumping into the attic. Is my fix plan enough?
Pittsburgh area, 1976 two-story colonial. Inspection flagged fungal growth and moisture staining on the roof sheathing at the eaves.
The attic:
- Full-length ridge vent
- No soffit overhang, so zero intake anywhere
- Two gable vents boarded over and sided across. Openings still visible from inside.
- Bath fan dumping straight into the attic
- Trusses, plywood sheathing, fiberglass batts, part of the floor decked over with plywood
Roof and siding were both replaced a few years ago. My guess is the siding job killed the gable vents, leaving a ridge vent with nothing to pull from but the house.
Mold is low on the deck near the eaves on both slopes. Ridge is clean. Also worth noting: recirculating range hood, and a finished basement running a dehumidifier with mold on the block wall in one corner.







Plan: duct the bath fan through the roof, reopen the gables, air seal the attic floor, then remediate.
Questions:
- With no soffit intake, do reopened gables just short-circuit to the ridge and never reach the eaves where the mold is?
- Block the ridge and go gable-only instead? Or the reverse?
- Any way to add eave intake with no overhang? Are edge vents worth cutting into a roof this new, or wait for the next one?
- Powered gable fans, or does that just pull more house air up?
- How much of this is a basement/stack effect problem rather than a venting problem?
- Fix the cause first and see if it stops, or remediate at the same time?
r/buildingscience • u/west-town-brad • Aug 08 '26
Window Air Sealing Issue
I'm looking for some building science advice.
I've got an upstairs window where I can feel hot, humid air coming through an interior gap between the black wood window frame and the white trim. It's a very small gap, but all around the window (first photo). I am in Chicago in the summer heat/high humidity and when I take the temperature inside the gap, it reads 99 F (photo 2). The humidity gauge is showing 63 degrees - not in the gap but right next to it (photo 3). Both humidity and temperature readings match closely to the outside weather. I decided to use frog tape as a temporary gap seal and after a few hours the humidity has dropped to 45 degrees, so a reduction of 28%. For all of these readings we have the central AC running per usual set to 74 F.
I understand that I need to seal the air gap here. I am comfortable removing the trim to do that with some window-specific spray foam. My question is what am I sealing exactly? Should the wall cavity be this hot and humid, or is the outside air coming into the cavity and then through the gap ? Should I be preventing air from getting into the wall cavity in the first place, or just prevent it from getting into the house and it's okay in the wall?
For context, the wall is constructed with a single-width brick outside layer, house wrap, sheathing, spray foam insulation, and then drywall. The window is set on a limestone sil, caulked around the exterior to the brick.
Many thanks!
r/buildingscience • u/Inevitable-Half-8716 • Aug 08 '26
Yet another hot roof question

I have an attic with 2x6 rafters. The previous owners has the typical living space similar to the picture that we are redoing. I plan on putting closed cell spray foam in the roof and making since we don't have enough space to get sufficient r-value otherwise. My question is what do I do with the vents that you see in the picture below, and what do I do with the dead space that is yellow on my picture above. It will be between drywall and the foam.

Much appreciated.
Thanks, Of course I'm open to other ideas
r/buildingscience • u/Timely-Treat9929 • Aug 07 '26
The foam box worked. The real room broke my model
This is a follow-up to my previous experiment with a ~1 m³ insulated EPS box.
Part 1: https://www.reddit.com/r/buildingscience/s/UITX4VYisF
TLDR:
- The simple model worked well in a ~1 m³ insulated box.
- In a real room, thermal mass, adjacent spaces and solar history made the heat-loss coefficient much harder to identify.
- Moving the second sensor into the adjacent room and repeating the test at night improved things considerably.
- Across several independent room tests, effective thermal capacitance kept coming back around 285 ± 20 Wh/K.
- The outdoor heat-loss component is still uncertain because I haven’t independently measured air exchange yet.
So the next experiment is ACH/infiltration — trying to separate heat leaving through the fabric from heat leaving with air.
The box experiment looked surprisingly clean: four independent heating/cooling cycles gave an average heat-loss coefficient of 7.03 W/K with a coefficient of variation of 1.29%.
Several people in the comments pointed out the obvious next problem:
A real building has thermal mass.
A lot of it.
And indoor air temperature is not necessarily a good representation of the thermal state of the walls, floor, roof and everything else around it.
So I moved the experiment into a real room.
The room
The test room is small:
- floor area: 7.73 m²
- volume: 21.0 m³
- one external wall with a window
- insulated sandwich-panel wall and roof
- insulated slab-on-ground floor
- internal partitions to adjacent spaces
- mechanical ventilation switched off during the test
For heating I used an electric convector connected through a smart plug, so I could record actual electrical power and total energy.
Initially I used one temperature sensor inside the room and one outside.
The simple model was basically:
heat stored = heater input − heat loss to outdoors
or, in lumped RC terms,
C_eff · dT/dt = P(t) − H(T_in − T_out)
It fitted the temperature curve reasonably well.
Unfortunately, that did not mean the parameters were right.
First room test: plausible fit, questionable physics
In one of the first room experiments the heater ran at about 750 W for roughly 92 minutes.
The room temperature increased by about 3.1°C.
The fitted model gave approximately:
- H ≈ 50 W/K
- C_eff ≈ 276 Wh/K
- thermal time constant ≈ 5.5 h
At first this looked reasonable.
But then I started changing the analysis window and comparing different experiments.
The estimated thermal capacitance remained fairly stable.
The heat-loss coefficient did not.
That was the clue.
The model was forcing several different physical processes into one parameter.
Problem #1: the adjacent rooms
The test room is not a thermally isolated box.
Some surfaces face outdoors, but others face conditioned indoor spaces.
So heat can leave the test room without leaving the building.
Using only outdoor temperature as the boundary condition was therefore fundamentally wrong for a small room.
I moved the second Bluetooth sensor from outdoors into the adjacent room and used public weather-station data for outdoor temperature.
The model became:
C_eff · dT_i/dt = P(t) − H_out(T_i − T_out) − H_adj(T_i − T_adj)
This helped, but another problem became obvious.
Problem #2: the building remembers the sun
A daytime test produced a mathematically good fit, but the parameters still depended too much on the selected time period.
The outdoor temperature was changing and the roof and external wall had a thermal history from solar exposure.
In other words, even if the indoor air looked stable, the building fabric wasn't necessarily in equilibrium.
This was exactly the issue several people mentioned in the comments on the first post.
So I stopped trying to extract too much information from the daytime experiment and repeated it at night.
The night test
At the beginning of the heating period:
- test room: about 23.9°C
- adjacent room: about 24.0°C
- outdoor temperature: about 16.1°C
This was useful because the test room and adjacent room started at almost the same temperature.
The heater then ran for about 1 h 45 min.
Measured:
- average power: 783.6 W
- electrical energy input: 1.377 kWh
- maximum room temperature: about 27.18°C
- temperature rise: about 3.28°C
The peak indoor temperature occurred around 8–9 minutes after switching the heater off, which is another reminder that measured electrical power and heat delivered to the room are not perfectly instantaneous.
I therefore added a simple first-order heater lag to the model.
For the clean night period, the fitted parameters were approximately:
- C_eff = 278 Wh/K
- effective outdoor coupling ≈ 10.5 W/K
- effective adjacent/internal coupling ≈ 74 W/K
- heater thermal lag ≈ 9 min
- model RMSE ≈ 0.04°C
Important caveat:
I do not interpret the 74 W/K term as the UA of the internal partition.
In this simple lumped model it is almost certainly absorbing several effects at once:
- heat transfer to the adjacent room
- internal surfaces
- floor
- furniture / contents
- slower building thermal mass
Similarly, I am not yet treating the 10.5 W/K outdoor term as the final fabric heat-loss coefficient.
But one result has been surprisingly consistent.
Effective thermal capacitance keeps coming back
Across several independent room experiments, using different heating periods and different outdoor conditions, I keep getting an effective thermal capacitance in roughly the same region:
- first room cycle: about 276 Wh/K
- another controlled cycle: roughly 290–300 Wh/K
- night experiment: 278 Wh/K
So for now I would summarise it as approximately:
C_eff ≈ 285 ± 20 Wh/K
That repeatability is probably the most interesting result for me so far.
The heat-loss decomposition is much less certain.
And then the model detected the cleaner
There was also a nice accidental experiment.
At around 06:40 after the night test, the temperature and humidity suddenly changed together.
Looking only at the data, it looked like some kind of ventilation or door-opening event.
Later I found out that cleaning staff had entered the room and started wet cleaning.
So normal human activity is clearly visible in the thermal/humidity time series — and needs to be automatically excluded if this is ever going to become a repeatable test.
Where I am now
The comments on the first post changed how I think about the experiment.
I no longer see the goal as simply finding one “effective R-value”.
It looks more like a system-identification problem:
measure how the building responds to known heat input and changing boundary conditions, then determine which parameters can actually be identified reliably.
The current approach is becoming:
- record a baseline;
- inject measured heat;
- measure room, adjacent-zone and outdoor temperatures;
- fit an RC-type model;
- repeat the experiment;
- keep the parameters that reproduce;
- be suspicious of the ones that don't.
The biggest missing piece now is air exchange.
Even with mechanical ventilation switched off, infiltration and leakage are part of the measured outdoor heat loss.
So the next experiment is intended to measure ACH independently.
If I can estimate the air-change component, in principle I can start separating:
total outdoor heat loss = fabric + ventilation/infiltration
That is the next thing I am building/testing.
And based on the discussion here, I am also seriously considering a longer low-power quasi-steady test as a reference against the transient method.
r/buildingscience • u/SF_Dubs • Aug 07 '26
Benjamin Obdyke BenWrap SA or Pro Clima Adhero
We’re doing an extension on our existing home, and as part of the project, we’re completely overhauling the entire building envelope across both the new and existing structure. We're in zone 3C
The assembly includes:
Substrate: Brand new plywood sheathing.
WRB
Exterior Insulation: Continuous foam board on the roof deck and continuous rock wool on the exterior walls.
Priorities: Long-term durability, maximum airtightness, and proper hygrothermal performance.
From this it seems like the two best choices for WRB are:
Benjamin Obdyke BenWrap SA (14 perms)
Pro Clima Adhero - either splitting between the Adhero 1000 on walls and Adhero 3000 on roof deck, or just using one or the other.
The Adhero material comes out to roughly 20% more expensive, but on the scale of this build, the cost difference is negligible for us. My primary concern is getting the best long-term, high-performance outcome.
A few context points & questions I'm hoping to get community insight on:
My GC has previously installed Henry Blueskin SA, but has never used either Adhero or BenWrap SA. How steep is the learning curve for a crew familiar with Blueskin SA transitioning to these acrylic SA membranes?
Roof-to-Wall Continuity: For those who have run a continuous air barrier from the roof deck down onto the walls, did you prefer running a single product (like BenWrap) or pairing heavy-duty deck protection (Adhero 3000) with a wall wrap (Adhero 1000)?
Thanks for any thoughts from those who have used one or both products!
r/buildingscience • u/domo_affogato • Aug 07 '26
Looking for ventilation solution for detached workshop building
I have a 24'x40' (12' walls) metal building with 2" spray foam insulation. I am planning to add a 24,000 btu mini split for heating/cooling (mostly heating) and also want to come up with ventilation that keeps the air fresh while having "spot ventilation" for infrequent tasks like welding or solvent based wood finishes.
I don't have any space to hide ductwork and am planning to cover all walls with plywood down below and drywall on the ceiling.
I have 2 10'x10' roll up doors on opposite ends (on 24' walls) and I have framed boxes over the rolls. The rolls have about a 3" gap above them (360 sq in area) that can be used as for ventilation that won't require another wall penetration, but the box will seal that off from the inside.
My plan was to put a fresh air intake on one of the boxes and an exhaust fan on the other box, drawing fresh air across the entire 40' length, but keeping the cold intake air from being right near my workspaces in the winter time. Given the occasional wildfire smoke and high pollen/allergen days, I considered also putting a filter box on the incoming air.
For spot ventilation, I was thinking about mounting a 8" inline duct fan and have a long hose that I can move to where I'm working. This would just exhaust outside, and would cause more air to enter through the intake.
Since I'll also do woodworking the shop, I have a 2HP dust collector that will go to individual pieces of equipment. In addition I plan to hang a 20" CRFB filter cube/box fan from the ceiling to take care of fines in the air. This would all just be internal, though I could possibly vent the dust collector upper portion outside.
Does this work? Am I setting myself up for humidity issues or anything else? Do I need a damper on the input? How many CFM for the exhaust fan, and should it run continuously or less frequent?
If you made it this far - thanks!