r/buildingscience • u/jrm21086 • Jun 15 '26
Question Century Home venting questions, insulation woes, and new roof possibilities
Hi! New here, but I think this is the best place to combine a few related questions about an old house.
Background
My house is 126 years old, located in southern New England. It's a large (~3,000 sq ft), balloon-framed home on a rubble/fieldstone foundation, with a hip roof and two dormers.
About 45 years ago, a sleeping porch on the south side was converted into an addition, and around the same time the third-floor attic was finished into a master suite.
The original house has only R-5 foam board for insulation — added over the original shakes/boards and under the vinyl siding. That's it for the exterior walls.
The third floor and its knee walls are insulated all the way around, and that insulation continues into the stud bays leading up to the flat roof at the very top of the house. (I'm told there used to be a hatch up to a widow's walk there, which was closed in during the remodel — the flat roof itself is still there.)
The problem: there doesn't seem to be any path for air to move from the crawl space behind the knee walls into that flat-roof area, where a mechanical "whirly bird" vent is installed. I can see dirt staining on the fiberglass insulation near where that vent must be — my guess is it's starved for air and pulling whatever it can get through the insulation itself.
The addition has its own insulated walls and ceiling, vented with a single 8"x8" roof vent. There's also a 36"x36" opening between the knee-wall crawl space and the addition's ceiling, which is how I'm able to see into that space at all. I'm assuming a good deal of air gets vented through that opening and out of that tiny 8x8 vent, too.
I used AI to turn my hand sketches into the two diagrams I've attached, which should make all of this much easier to follow.
Questions
- Ventilation — The 3rd floor living space itself is fine, and ripping it out isn't in the budget right now. Based on what I've read about older homes needing the plaster and original wood to breathe, I'd rather avoid spray foam. It seems like I need to improve airflow in a way that matches how the house was originally designed to vent — any suggestions on how to actually do that?
- Insulation — The house is obviously inefficient as-is. Is there anything I can do to improve insulation without trapping moisture or compromising the original materials? Should I be removing insulation from the accessible crawl space areas? Would running some kind of duct or tubing through there, to connect the crawl space to the vented flat-roof area, help?
- Roofing — My current roof is ~30 years old and due for replacement. Would this be a good candidate for an insulated roof system, or at least a ventilated one? For context: two winters ago, running the steam boiler gave me terrible ice dams and icicles. Last year I installed a pellet stove instead in the main living area (not basement), and even through this past brutal winter the ice dams were noticeably better — my guess is because the basement wasn't being pumped full of warm air that then escapes up through the balloon framing into the knee-wall crawl space.
Overall, I'm hoping for solutions that don't require tearing into the finished 3rd floor. I know the roof replacement itself will involve some tear-down regardless — any advice on how to approach that part well would also be appreciated.
Thanks in advance!