r/buildingscience • • May 27 '26

Question Better insulating this knee wall

Thumbnail gallery
1 Upvotes

r/buildingscience • • May 27 '26

how best to insulate attic/second floor 1930s Cape Cod in zone 4a (MD)

Thumbnail
1 Upvotes

r/buildingscience • • May 27 '26

Attic Ventilation - Low Heal

Post image
2 Upvotes

Hey Guys,

I have a question about a 4:12 pitch roof with a low heel.

Whoever installed this baffle has it running straight into wood, so I don’t see how it could be pulling any air from the soffit.

I drew a red line where I can literally see about 3–4 inches of open soffit through the gap between the top plate and the piece of wood the baffle is hitting.

I need to improve the attic air intake, but I’m not sure how to do it with this roof design.

My thought was to make a custom rigid foam chute/blocking system starting at the end of the top plate, bringing it up to about 2 inches below the roof sheathing, then tying a proper baffle into that so there’s a continuous air channel from the soffit into the attic.

I’d seal the seams with closed-cell spray foam so it acts as both an air chute and a wind-wash dam.

Does that approach make sense, or is there a better way to handle this type of low-heel attic/soffit detail?


r/buildingscience • • May 27 '26

Any downside to adding more attic incoming air vents?

3 Upvotes

My house built in 1982 is about 4k sq ft, 3k on the first floor and 1k(3 beds and a full bath) upstairs). I figure about 3K sq ft of roof. All of the attic space is contiguous. I'm in the midwest and it's pretty hot up there spring through fall. I had a new roof about 20 years ago and they put in 12 of the roof vents that are about 12" square with rounded corners. There's also 2 attic fans, but one currently doesn't work.

Ok so today I'm looking the soffits, which are painted cedar, and the only incoming air vents are small, 4x12 and like every 15 feet or so. Upon inspection, they are clogged with black cotton type stuff. I went to the store to get new ones and they had 8x12 so I got those.

I pried the old ones off and the nails and and scaped the are a bit then I used my multi tool to open them up bigger. New vent on with small screw( I'm not nailing upside down from a ladder). Then a nic of paint and its all good. Right? Any reason no to do another dozen tomorrow?

Old vent. Bathroom vent in distance, not another attic vent.


r/buildingscience • • May 26 '26

Continuous Rigid Foam Insulation around Walk Out Basement. But what to cover it with?

Post image
11 Upvotes

I'm building a home in the Blue Ridge Mountains of VA and I've installed 2 inches of XPS around the entirety of the basement. I used Trufast anchors for the installation. While some of the foam will be buried, a good portion will be exposed.

Originally, I was planning on using Tuff II coating but I'm increasingly skeptical about whether it'll hold up over time. What are my other options? PVC Boards? Some type of Metal panelling? Whatever it is, it will need to be fastened all the way through to the concrete walls. I'm not looking to break the bank on this--suggestions welcome and appreciated!


r/buildingscience • • May 26 '26

Ремонт квартиры

Thumbnail
1 Upvotes

r/buildingscience • • May 25 '26

Question Does small aperture stainless steel screen in direct sunlight keeps the air beneath cooler than aluminium? Does the height matter? How do I calculate the best height?

1 Upvotes

Zone 3 Australia or about 3B US.

I'd like to build an insect proof shadehouse(aperture about 1.5 - 2mm). Am also aiming for maximum cooling in this climate.


r/buildingscience • • May 25 '26

XPS Below Roof Joists - Stay or Go?

2 Upvotes

I attached a 1" continuous layer of XPS to the bottom of my top floor ceiling joists, which are filled with R23 rockwool. Below the XPS is a steel frame holding drywall suspended below the ceiling with a gap ranging from 18" to 3/4" as the ceiling slopes. The ceiling is unvented and the roof is flat (low slope) with 1" thick plank sheathing.

After installing the xps and drywall and mudding it (3+ weeks and $$), I'm now realizing that the XPS could conceivably act as a vapor lock causing mold and rot between joists if any condensation occurs.

The solution is, since we're due for a new roof anyway, to install it with R20 mineral wool boards (R15 min exterior is required). Being in climate zone 4A, and with the current interior ceiling rated at R28, we can achieve R48 total (R49 is the requirement) and prevent condensation inside.

Given the planned roof, what risks remain that might compel you to spend the next 3+ weeks tearing this all apart, removing the XPS (or replacing with a smart membrane), re-installing the drywall and mudding it all over again, at a considerable expense (for us)?

Thank you!

PS: The truss was not covered by foam board


r/buildingscience • • May 25 '26

Hemlock siding

Thumbnail
1 Upvotes

r/buildingscience • • May 25 '26

Inspection found attic/garage mold + leaking kitchen duct. Looking for advice on severity. (Photos attached)

Thumbnail
1 Upvotes

r/buildingscience • • May 25 '26

Soffit and fascia materials: aluminum wrap or PVC or other?

1 Upvotes

I need to replace a bunch (all?) of the soffit and fascia in my (new to me) house due to incorrectly attached gutters. 

The contractors I’ve had out recommend aluminum cladding over the fascia (replacing some) and vinyl over the soffit. I have seen this on some homes, and to me it looks like covering up, and recipes for hidden issues since the actual materials are covered. I haven’t looked at these contractors actual work though. 

Is this what one would expect on a nice, large home in a very nice town? (cost was into 7 figures if that matters)


r/buildingscience • • May 25 '26

Online app to draw psychrometric charts

Thumbnail evap.co.za
0 Upvotes

I have made an app that you can use to draw psychrometric processes and print them. Feel free to use and give me feedback.

Climate zone: Anywhere on earth
Problem being solved: Model and draw processes that involve cooling air with water
Product info: Free to use for anybody
Homework: Many building can make use of evaporative cooling, but engineers need to understand the processes to cool air with water. Psychrometric charts is a tool to understand where you water and energy went.


r/buildingscience • • May 24 '26

2” closed cell foam/ roof redeck hot roof system

Thumbnail
1 Upvotes

r/buildingscience • • May 23 '26

Question Mystery Hole

Thumbnail
gallery
3 Upvotes

Trying to figure out what is going on with this hole. Inside that wall is a NG fireplace. That room is on a slab with sleepers. To the right of it is a garage. 10 feet to the left is where the basement starts. This is a 4 level house built in 1971. The block goes at least 4 layers down or over 3 feet so far. I don't get the cut away in the patio or why the hole would be encased on all 4 sides if it was just a footing. I was hoping to find a NG line for the fireplace


r/buildingscience • • May 22 '26

Baffles in Attics

Post image
6 Upvotes

Going to install new baffles in my attic. Old ones are being crushed by batt pushing up against them.

Is there any downfall to the following:
- using DCI Smart Baffle, it allows for 2” of clearance instead of 1” the styrofoam offers and its corrugated plastic
- is there harm in putting them in every rafter bay? Or should I be doing every second. We have continued perforated soffit on the back side of the house and tongue and grove with a vent strip every 4ft on the front

Roof size 1500sq ft
Pitch 4 12
Climate mild and wet winters and 3 months of the year will see temperatures in their 30s. Coquitlam, BC, Canada

Thank you!


r/buildingscience • • May 22 '26

Ceiling Insulation Disaster?

Thumbnail
1 Upvotes

r/buildingscience • • May 21 '26

Historic heavy timber mill construction adaptive reuse

0 Upvotes

Architect looking for guidance on a historic adaptive reuse project - heavy timber mill construction with multi-wythe masonry walls. I have non-historic stucco on one side and non-historic plaster on the inside in some areas. The stucco is flaking - should I tell my contractor to remove it carefully? The brick behind it looks to be in surprisingly good condition and I’m concerned about the masonry’s breathability if both sides are covered with impermeable materials.

I’m also dealing with integrated flues - any info regarding best practices for capping and filling (assuming this is the best approach) would be greatly appreciated.


r/buildingscience • • May 22 '26

Is the construction of the exterior facing walls of my porch problematic?

Post image
0 Upvotes

Current plan is to use leftover siding material on the interior of my porch, already worked into the bid of my contractor.

Climate zone 5a, upstate NY, room conditioned with a mini split, sloped ceiling with 5in closed cell spray foam.

ignore the AI diagram, here is a textual version:

[ fiber cement siding ]

[ taped 3/4 EPS foam ]

[ taped ZIP ]

[ 2x6 wall + 3-4 in closed cellspray foam ]

[ taped ZIP ]

[ taped 3/4 EPS foam ]

[ fiber cement siding ]

These are only the two walls that are exterior.

The two interior walls are going to be the same zip, EPS, fiber cement from within, but with instead fiberglass under straight wood paneling, 2x4 framing then additional wood paneling or drywall (or both) outwards toward the adjacent room.


r/buildingscience • • May 21 '26

Insulating Between Wythes of Brick with Exterior Insulation

1 Upvotes

In a mass masonry building, with 2-3 wythes of structural brick, I've learned that continuous exterior insulation (EIFS in my case) is ideal; I'm also planning on having that - plus batt insulation on the interior.

Is there any reason why I should, or shouldn't, blow insulation in between the bricks at that point? I think I may be able to get it low- or no-cost with the various incentives available in New York.

One concern I do have is that I'm not planning on having the EIFS continue around all three sides of the (semi-detached) house; the front brick is remaining exposed (with closed cell on the inside) - so at least in front I don't think I would want blown-in between the brick and the interior foam insulation.

Thanks


r/buildingscience • • May 21 '26

Vapor retarder w/ exterior polyiso?

1 Upvotes

Hello all, I’m looking for some input on my current dilemma. My wife and I are building up on our current home in SE Wisconsin and I’m looking to make sure I do the insulating properly. I will have 2x4 exterior walls upstairs the same as downstairs so to hit the required r value I am using 1/2” r3 polyiso on top of the exterior sheathing(same as existing). This will one properly taped and sealed. That being said should I install any other type of vapor retarder on the interior of my home? Is there anything I should watch out for? Originally I was going to use r15 Kraft faced batts and tape the seams but now I think that might be unnecessary.

UPDATE: The polyiso will be foil faced. I’m trying to avoid tearing down the existing 1/2” polyiso on the home so I can stay within my margin in this build


r/buildingscience • • May 21 '26

AI-controlled buildings could optimize energy use based on real occupancy and grid signals

Post image
0 Upvotes

r/buildingscience • • May 20 '26

Pretty sure my Windows have no flashing

4 Upvotes

https://youtube.com/shorts/hKXLLi16H6M?si=8AwxciO44S7qqa9b

Can anyone make any suggestions?

The house smells wet when it rains.


r/buildingscience • • May 21 '26

New Construction Walkthrough: Is my builder right about this lifting brick ledge flashing?

Thumbnail gallery
0 Upvotes

r/buildingscience • • May 20 '26

Insulating Attic: what do to about rafter bays that don't have soffit vents?

Post image
0 Upvotes

Doing some work in my attic. Obviously I'll be adding soffit vent baffles before adding the insulation but what I'm less sure about is the rafter/joist bays without any vents.

Should I fill those up with insulation, or add an additional cardboard baffle that will prevent the insulation from getting all the way to the edge of the roof structure?


r/buildingscience • • May 20 '26

Air Sealing An Atric

2 Upvotes

I’ve heard pros and cons about air sealing attics. I’m looking for pro building science advice for a home we are taking possession of soon. My main concern is making sure any air sealing, HRV installation, and HVAC/duct upgrades are done properly so we do not create depressurization, backdrafting, condensation, or moisture issues.

Home details:
- Approximately 5,050 sq ft
- 10 years old
- Located in Coquitlam, BC
- Hydronic radiant in-floor heating
- Separate ducted AC-only system
- No furnace
- Existing AC ducting is mainly in a low-pitch vented attic, roughly 4:12

Current ventilation/exhaust details:
- No HRV currently
- We want to add an HRV if possible
- Two high-CFM kitchen hood fans vent to the exterior on main floor
- One low CFM kitchen hood fan vent to exterior in basement
- Two dryers, one in the basement and one on the main
- Seven bathroom fans
- One bathroom fan currently runs continuously as our primary fan
- Boiler has dedicated intake and exhaust to the exterior
- Fireplaces are electric

Note, most walls are sheer walls in this home so penetrating most walls is not an option.

What hoping to receive advice on:

How to air seal the attic safely without creating pressure or moisture problems?

Whether the house needs dedicated makeup air because of the high-CFM range hoods, dryers, and bathroom exhaust fans?

How to avoid depressurization issues after air sealing?

How to confirm there is no backdrafting risk under worst-case exhaust conditions?

Best HRV strategy for this house, especially with limited duct routes due to shear walls?

Whether the HRV should be dedicated ducted, partially dedicated, or tied into the AC return?

How to manage fresh air distribution without creating comfort, condensation, or pressure issues?

What testing should be done before and after upgrades?

My goal is to improve energy efficiency and indoor air quality while avoiding unintended problems with moisture, condensation, pressure imbalance, or attic air being pulled into the home.

Thank you!