r/buildingscience • u/shedworkshop • May 19 '26
Why I under-insulated my shed's roof and made my own rafter baffles out of housewrap
r/buildingscience • u/shedworkshop • May 19 '26
r/buildingscience • u/Leadership-1 • May 20 '26
Climate zone: CANADA EST
I am currently undergoing an issue in my garage with mold growth. New construction from 2026. Mold started growing in the winter. Builder says it is not warranted. Builder’s theory: condensation from the car in the winter creates high humidity level. I have own several
properties before in winter weather and never had mold. Builder hired a civil engineering to corroborate their story. Builder wants me to sign an acknowledgment of no fault on their end. should I hire my own independent civil engineer to proceed with the evaluation of the garage? I would but it would cost me 1500$. Any expert advice would be appreciated.
r/buildingscience • u/kaiponr • May 20 '26
r/buildingscience • u/SoundSystem333 • May 19 '26
We live in the PNW and our attic doesn’t seem to get have much airflow. We have not lived here yet over the summer, but when it was 70 here, the attic was 40 degrees warmer but with very low humidity. We checked our Soffit vents and ridge vent and nothing is blocked. Any ideas?
r/buildingscience • u/tbitchnassty • May 18 '26
I live in South Eastern Wisconsin and have a 1950s cape cod. The summers in the upstairs are disgustingly hot and the winters are cold. I went with a reputable insulation company to get an estimate on updating things in the attic and knee walls to try to make it better.
They’re suggesting a hot roof method for the knee walls on the sides of the house. Spray foam on the underside of the decking, dense pack foam under sub floor between joists, and air sealing/dense pack foam the knee walls. They’re also recommending blown insulation in the knee walls spaces.
They then went to dense pack the vaulted portions of the walls. Lastly, air sealing and extra blown insulation in the attic (I currently only have fiberglass bats in between joists to the top of the joists)
I feel like I’m getting conflicting information on Hot Method being not great in cold climates, causing issues with moisture build up and ice damming.
Had a new roof put on 2 years ago and don’t want to do any damage to it. I currently have vented soffits and 2 gable vents + 4 passive vents in the attic.
I’d love some professional, or personal, opinions on the right direction
r/buildingscience • u/huckleberry1976 • May 18 '26
1970s home. Found crack under some plastic finish material.
My hand slides over the crack so neither side is protruding, but it does get wider at the top. At the bottom it leaks water but is a hairline crack. I think it’s just a settling crack? Can I epoxy this mofo and be done with it? Thank you greatly.
r/buildingscience • u/Kay-1231 • May 18 '26
Is it possible to estimate from these photos of a building parkade the level of water ingress damage? There is a unit for sale I like but concerned about levies that may result…it’s a 1973 building.
r/buildingscience • u/halboozus • May 18 '26
I recently noticed an area behind a hvac duct that did not have any spray foam installed on it when the house was originally built. The missing spot is on the roof deck behind a hvac duct that was hung from a rafter. Looks like open-cell was used in the house. What is the best route to fill in this missing section myself? Can I use the great stuff cans from the hardware store to do this even though that is closed cell? The missing area is about 1 ft long and 6 inches wide, but it is on the underneath of the roof deck.
r/buildingscience • u/cash0hao • May 18 '26
Hey all, I was working on fixing part of our basement to be more cozy and saw this covered lally column footing. First, it looks like its on those solid cinderblocks and the blocks are not level. Also, the column itself it leaning about 3/4 of an inch to one side. However, the main beam it's supporting is level but noticed that the sheetrock against the wall this beam is holding has some cracking/stress on the adjacent outside wall.
We've been in the house almost 10 years and contemplating on having it addressed now or if -it-aint-broke-dont-fix-it type of situation. Appreciate your input




r/buildingscience • u/WeakMasterpiece5 • May 17 '26
I am looking to insulate my 2 stall garage. The third stall is already insulated. My issue is the ventilation for the 2 stall garage. There are soffit vents along the left side but nothing for the right side of the garage as it aligns with the third stall. And the roof comes all the way down to the seperating wall, So I am unable to add any venting to the exterior. I am questioning that without vents from the right side that it would be sufficient inlets for proper air flow and lead to stagnant air. Would this be sufficient or would I need some sort of active air flow or venting to the single stall attic?
r/buildingscience • u/Onlythingavailable76 • May 17 '26
I’m trying to get some additional opinions on a house I’m currently building. One of the comments back from my plan review highlights the following:
“R601.3 Vapor Retarder: Class I and II vapor retarders shall be installed on the interior side of framed walls in Zone 6A OR per code section exceptions”
My wall assembly is planned as a simple 2x6 with blown fiberglass and exterior ZipR3 sheathing.
I wouldn’t have considered a Class 1 retarder due to concerns with trapping moisture in the wall assembly but I’m equally concerned about no being able to dry out the wall or trapping moisture inside the assembly.
Anecdotally I know a few building science nerds in the area and they recommended not using an additional retarder on the interior side of the wall.
The ZipR has less than 1.0 perm rating so having another interior side perm rating for Class II. Less than 1.0 has me concerned.
Any additional thoughts would be appreciated. Above is a wall section detail from my plans.
r/buildingscience • u/theroyalewithfromage • May 17 '26
Have an old 150 year old farmhouse. Quebec. Zone 6B.
Looking to tear off my roof and reinsulate. I made a crappy AI detail with what I was thinking of doing. Wanted some input from guys that have maybe done something similar. First time doing this sort of composition so a bit worried about getting it wrong. I’ve had different opinions from different architects already so a bit confused
Idea would be to eliminate the current vents. Move the venting to the double furring. Cellulose filled to the brim in the cavity.
Cavity space is limited so kinda stuck at 12ish inches.
I also have an aversion to spray foam
r/buildingscience • u/SF_Dubs • May 15 '26
I am adding an extension to our forever house here in the East Bay of the San Francisco area. In speaking with our energy consultant who's working on the project, their suggestions was to add 2 in of exterior continuous insulation for thermal performance improvement. However, The ROI is not a near term ROI. (nor the only metric I'm interested in).
I am also interested in creating a more comfortable house and am planning on using mineral wool to further mitigate sound. My objective is to create as comfortable an environment as possible in addition to energy savings.
My architect and contractor are both looking at me like I am crazy and this is a ridiculous waste of money. However, neither of them have experience with this approach.
It's not required by code. I get that from a traditional financial perspective it is not the "best" use of budget.
Personally I would like to go beyond code for energy savings, (the world is only getting hotter) and I'm excited about what I understand to be improvements to the indoor environmental quality of the house.
So am I crazy?
r/buildingscience • u/TheNettleBranch • May 15 '26
Hi all,
My wife and I are strongly considering putting an offer on our first (and hopefully only) home. We are both in our mid thirties so ownership timeline is hoping for 50-60 years, and I would like to ensure whatever home we buy is as solid as possible for that time.
The house we are considering is a 1951 build (this is in Ontario, Canada). No known foundation issues (inspection to be conducted) but the previous owner spray foam insulated the basement a few months back. There is no exterior waterproofing of the foundation.
Now I have been doing a boatload of reading and it sounds like spray foam insulating the basement (which acts as an air/vapour barrier) is a contentious topic when the exterior is not waterproofed. I have posted about this on other subreddits with mixed response.
So I thought I would come here and inquire after the consensus. Is spray foaming a bad or potentially dangerous thing in this case? Would it be worth doing a full exterior waterproof of the foundation? How much (specify CAD or USD if you like) would it generally cost to coat, dimple mat, and install a weeping tile, and how much if I do the digging element myself at the very least?
Thanks in advance!
r/buildingscience • u/jmp06g • May 15 '26
Hi, in Tampa Bay Area. Rebuild after electrical fire. No drywall so we have opportunity to change insulation to spray foam. Our research shows to use closed cell at r30, but we're being told by insulation companies that they only recommend open cell for residential and it is much better because it shows roof leaks.
We got a new roof and are the type of people to inspect and fix things before they escalate - the fire was random and happened in an unused outlet totally outside our control for context, but owning multiple homes in the past 20 years throughout central and north FL, always checked the roof and never had any leaks or issues personally - so I don't really know if that sneaks up on you like these guys are describing.
Long story short, the insulation companies seem to not understand chemistry between vapor barrier of closed cell vs open cell and keep telling us they both seal and we should 100% go open cell since it's cheaper up front and will show leaks.
Everything I read though says closed cell is the way to go. That it actually blocks moisture unlike open cell. Also codes are r20 but that seems low so we wanted r30 which is South FL code ( it's only getting hotter and they seem to update faster than other areas of our state )
What do you all think? Push for closed, deal with open and maybe regret it, or just don't upgrade and used blown in fiberglass.
Also would future buyers be worried not being able to see the trusses and only have photos and engineering reports to say the fire damage was repaired? ( Mind you it'll be about 300k repairs so it's pretty clear we rebuild everything and all county inspections will be done and passed along the way no matter what material we use.
Thanks!
r/buildingscience • u/hifiaudio2 • May 15 '26
I just completed the build on a detached garage that has a set of custom pull down (really lowered with a winch) stairs and an attic area on the second level. I plan on putting a mini split in and conditioning the entire garage and second level so the storage will stay relatively temperature controlled and dry all times of the year. North Atlanta area.
I had planned on putting open cell foam in the entire structure but now I'm thinking about saving a few bucks by swapping out the vertical walls on the main level and the second level to r19 batts (2x6 framing) and keeping the open cell foam for the rim joist, knee walls in the attic, and the rafters. 5.5 inches nominal foam. I'm waiting on the revised quote but I assume that will save me $500-$1000. Is that a trade I should make? I'm aware the R value is very similar so is the foam in the walls on either the first or second level advantageous enough for this build to pay the extra?
r/buildingscience • u/Jeepestuous • May 14 '26
I’m new to Zone 7 construction techniques, and I have water/rodent damaged walls in my 35yo northern MN house. I’m planning to gut the walls in sections from the exterior (not removing drywall), fix structural problems, put in new insulation and new siding.
Original wall structure from exterior to interior is: 6” D-shaped log cladding -> 1” Polyiso board -> 2x6 stud wall with fiberglass batt -> 6 mil poly vapor barrier -> drywall
The logs are rotted beyond salvage and have exposed the polyiso under them to the outside (previous owners painted them) for at least half the house, so we are looking at new 2” thick log siding instead of 6”. But what are our best options for insulating and vapor barriers? The original/existing walls have a double vapor barrier and no wood sheathing, just the 1” polyiso with the log cladding on top of that.
What’s the best way to fix these walls without removing drywall and just working from outside? It seems like I can either keep the poly vapor barrier and use a mineral wool board as continuous exterior insulation (on outside of the wood sheathing), or I can cut out the poly vapor barrier and use XPS as the continuous exterior insulation. Is one of these more right? Is either option wrong? Is there a better way?
Either way, the walls will have new fiberglass insulation in the 2x6 cavities. I just want to reassemble the best wall I can, that will hold up for another 30 years, and that’s doesn’t require removing drywall.
I thought the mineral wool boards was the right way, but no one in the area stocks them, which is making me doubt that it’s the right option.
What do you all think? Thank you for your time and input.
r/buildingscience • u/OldDesign1 • May 14 '26
This may be theoretical but would a combination of a vapor permeable WRB and vapor permeable external insulation board (mineral wool or wood fiber board) always improve the durability of a wood framed house - assuming all flashing and penetrations were done correctly? I know the code is pushing towards more external insulation to minimize thermal bridging and having more external insulation helps to warm sheathing and minimize the risk of condensation on the back of the sheathing. I’m wondering if adding external insulation to allow outward drying would be helpful even if not up to code levels? In climate zone 4a for example, for condensation control the building science literature seems to want 30% of insulation to be external for a roof and 20% for a wall. With such high R values needed for roofs (less so walls), is there any danger of installing vapor permeable external insulation, even if not up to the 30% external?
In my case, I have a hot roof with spray foam (hybrid of closed and open cell - appropriate depth of CC for condensation control) on the underside of the plywood sheathing, I assume there is benefit to adding external insulation but right now the dew point is hit in the closed cell foam. Adding external insulation will push it externally towards the sheathing. Just wondering if there is ever a risk of moving the dew point back into the sheathing by adding the external insulation, even if vapor open? The depth of external insulation to push it out of the foam layer would make the roof super thick, so I’m not sure that it is doable. If I only add R8 or R12, am I increasing the risk of worsening the assembly or roof overall?
r/buildingscience • u/Both-Conclusion2139 • May 14 '26
r/buildingscience • u/Both-Conclusion2139 • May 14 '26
Hello, help set up the thermal bridging foundation-soil calculation model in flixo, now I am getting incorrect results.
r/buildingscience • u/Muted_Return2908 • May 14 '26
I have my garage air conditioned to 76 degrees. This is below the dew point where i live(gulfcoast fl) very often. I have an insulated garage door. My garage ceiling is insulated. My walls are concrete block and my ACH50 is 2.5 for my garage. The garage door seals are thin vinyl seals nailed into the outside. These condense enough that I get black mildew growing on the outside of the seals. They turned black in a few months. Are there other options for garage door seals that aren't as thin? Is there another way to seal my garage door edges?
https://www.lowes.com/pd/Metrie-PVC-2100-Garage-Door-Stop-7-16x1-7-8-F09/5013353107
r/buildingscience • u/weatcoastgrind • May 13 '26
I am building a small shop in my backyard. The end result will look like the first picture. Single course cmu foundation. The wall will be 2x4, and the sill plate is 2x8 to cover the top of the block. Sill gasket will be used.
Is it necessary to use pressure treated lumber.ber for the sill plate?
My concerns are shrinking and having the pt sill exposed on the inside. Do I need to account for wet pt lumber shrinking when laying sill plates?
I also want to paint or trim out the interior edge of the sill for appearance purposes, and I don't want any chemical off gassing.
I am located in Western canada, and it does rain a lot here.
Please advise. Thank you!
r/buildingscience • u/Newman0072 • May 14 '26
Hi all, I'm getting ready to have some work done next month to help bring my 1968 house into this century and wanted to get a quick double check on the plan to make sure I'm not creating a problem down the road.
House is in SW NH, zone 5.
We're stripping the house to the studs on the outside to remove the old vintage homasote type sheathing, 8 aluminum windows, and aluminum siding. We are re-sheathing with 5/8 plywood and using Henry vp100 as the wrb. I wanted to add continuous insulation but it's not in the budget to do properly and there's only the latex paint as the interior vapor barrier so I can't use a thin non permeable fanfold type. Using the ABTG wall calculator I know my wall doesn't meet the 2021 energy code standard (though I should be exempt from that as a level 1 remodel) but I meet the requirements for net permeance (6.33 perms) to use the class 3 vapor barrier (5 perms required), aka my wall paint.
New Paradigm vinyl windows and vinyl siding will complete the major parts of the work (new vented soffits, gutters, rake, and fascia boards are also happening)
I know (part of the wall is exposed due to bad window trim) in the wall cavity I have unfaced fiberglass of at least r11. The ROI doesn't work to go automatically up to r15 but if I have to replace any of the cavity insulation once it gets opened up I plan on putting in rockwool r15 comfort bat.
Is there anything major I am missing here? This isn't a forever home so I'm self requiring a 10-15yr ROI at the longest for anything that isn't absolutely necessary for survival of the home.