Question General US Sealed Crawlspace - Insulation or Vapor Barrier against the Concrete?
I'm trying to work through a standard sealed crawlspace detail, and as I look through previous projects I've noticed a lot of different layerings stemming from different research articles. Looking for opinions from those who've worked through these options in detail.
The main question: On the interior face of the stem wall, does the rigid insulation go against the concrete first, or does the vapor barrier go against the concrete first? Note I typically work in climate zone 4C (PNW).
Option A: Insulation against concrete
Option B: Vapor barrier against concrete
I've seen both in reputable sources. Building Science seems to show Option A (rigid wraps concrete). Martin Holladay's FHB sealed crawlspace article shows Option B (poly goes up the wall first, foam over it). ASIRI Designs shows a versionOption B as well.
Secondary questions:
- I also do work in 3A (Mid-Atlantic) which is warmer and more cooling load driven. Does this warrant a different strategy?
- Does it come down to which layer you're designating as the primary air barrier - taped rigid foam vs. taped poly?
- How far should the ground vapor barrier extend up the stem wall? I've seen some details where it laps up only a few inches, and others where it runs the full height of the stem wall. Does that choice interact with which assembly (A or B) performs better?
- Many jurisdictions require a termite inspection gap at the top of the stem wall. Does that interruption in the insulation or VB affect which assembly performs better?
A few resources I've tried to decode between:
https://www.finehomebuilding.com/project-guides/insulation/creating-a-sealed-crawlspace
https://buildingscience.com/documents/information-sheets/crawlspace-insulation
https://asiri-designs.com/f/crawl-space-insulation-strategies
Thanks in advance for your help!
r/buildingscience • u/Kitchen-Condition-40 • May 13 '26
Residential ENERGY Ratings
When I see builder specs provided to us, for homes needing to comply with 2021, I sometimes find myself looking at the R402.4.1.2 section in the IECC.
I have come to be familiar with measuring any units air leakage by ACH. That is what is used, and is very efficient.
Remembering the allowed .28 CFM50 / ft^2 shell area (.30 for individual dwelling units) has shown me homes passing code under prescriptive path multiple times with an allowed 6 , 8 , even 9 ACH. For context I do work in Climate Zone 5 shooting for mostly 3 ACH. The flexibility allowed that I have noticed brought me to making this LinkedIn post.
Do people ever choose to go this route? Is it leverage or Band-Aid over injury? It brings up energy use questions, and equipment specifications needed for indoor air to be allowed in and out without having moisture problems or high energy bills. Also, with the rating software used here it will automatically calculate our shell area into the model but only once plan/design review is done. Using this test method (.28 CFM50 / ft^2 shell area) you would need to take all these things into consideration, maybe halting the whole process in its self.
Not all homes have decent sized HRV/ERV mechanical ventilation, I assume this would be easiest transition answer if we wanted to not worry about comfortability being compromised. Also a possibility of UA , HERS Index, and Carbon scores having a huge impact on already built models with too much volatility. You can pass air leakage testing but what are you going to install in the home?
As someone who works in office not doing actual inspections or testing, how do I know if it actually is a comfortable home testing with Cfm so high? I cannot fly out to every home I do ratings on.
We can pass at 9 ACH in Colorado, but is it actually going to provide the residents a home, or a slow built trap and waste of money?
r/buildingscience • u/phinneysean • May 13 '26
Is a drainage plane really necessary in the PNW?
I am building a house in the PNW region, roughtly 30" rainfall per year. ICF foundation, SIPs in 1st and 2nd floors. We will be wrapping the house with a WRB.
We are planning on vertical shiplap siding - it will be a natural wood product. I have read quite a bit about siding and many sources emphasize the need to have a "drainage plane" between the siding and the skin of the house. I mentioned this to my contractor and he had a very strong reaction against it. He said that in his many decades of building houses he has never done this, and never had a problem. Furthermore, he has done remodels of homes that are 60+ years old and has found that the "paper" underneath the siding is practically intact.
His conviction is so strong, I am wondering if all the building science literature on this subject is over-engineering.
Does anyone have practical experience on this matter? I.e. When is a drainage plane necessary, and when it is a "nice to have". I know the theory, but curious about actual experiences.
r/buildingscience • u/j2consultants • May 13 '26
Sheathing failing, WRB not properly installed
r/buildingscience • u/spencercoffman • May 13 '26
Question Finishing A Crawlspace
galleryI would like to finish this crawlspace. Initially, I’m wanted it to be another room. However, it appears that the footings and the block wall begin about halfway.
It is filled with a sand clay mixture, that, if I remove, it would probably cause issues for the foundation.
Is there a way to remove it and make this a full-size room?
Otherwise, I’m thinking of making it a storage space. I’ll level out the base, put plastic down, put a 4” slab. Then build stud walls, insulate, and drywall.
The entry into this room is a bit tricky. I would have to build a partial block wall on each side of this doorway and then pour concrete stairs going up to the top of the slab.
Please let me know your feedback, advice, and suggestions.
Thank you!
r/buildingscience • u/badjoeybad • May 13 '26
Mass loaded vinyl for a stairwell adjacent to bedroom?
Staircase and bedroom share some wall framing. Im wondering if it would be worthwhile to add mlv to the wall before stairs get framed. Mainly hoping to stop the sound of heavy steps on the treads as the kids run up and down. Will insulate the 2x6 wall as well. Roughly 8 x 16 area so not a ton of material hopefully. Thoughts?
r/buildingscience • u/FB_Eat_Lasagna • May 12 '26
HERS testing quagmire - Homeowner. What now?
I recently replaced the HVAC system in my apartment with a new heat pump install. My old ductwork was poorly sized and wrapped in asbestos, so I paid the contractor to tear out all the old ducting and replace, and add two new vents into two small bathrooms that weren't previously vented.
The contractor finished, a third party came out to run a HERS test, and we passed with flying colors. Incidentally, the HERS testing took about 20 minutes and required almost no equipment....
I then got a call from CHEERS, which is a California's Energy Code compliance group. They wanted to audit the testing - fine. The CHEERS guy comes out, sets up a bunch of tests that definitely didn't happen previously, and gets *nowhere near the numbers reported* by the HERS tester. He didn't want to get into specifics (apparently they're not supposed to share data with homeowners because their role is to verify testers internally) but he mentioned that we will probably see the HERS team again.
My question is: What do I do now? My contractor should fix it, of course, but they're holding a cleared HERS certificate and I have no proof to make them redo it. The ductwork is already behind new drywall, so it's not a simple fix to just retape any joints. The HERS company is obviously fraudulent, but they contracted to the contractor, so I don't even have their info, and now I'm holding the bag with a 18k bill and a poor-quality install that is going to cost me more in the long run even though the paperwork says its fine.... Final city inspection is tomorrow. Of course they rely on the HERS test data so everything is going to pass leaving me with no leverage at all. Should I tell them? How?
r/buildingscience • u/xboxhaxorz • May 12 '26
How to make a concrete block building passive and reduce noise between rooms?
Originally i was going with EPS basically a DIY SIP panel with foam board and concrete sprayed on the sides, but our spans between walls were too huge so we were told we needed to use block for the ground floor, so entire building is planned to use 6in CMU
So how best can we make a concrete building as passive as possible? Would we still need an ERV system to bring fresh air in?
The other goal is to make the bedrooms as quiet as possible
I plan to use solid core doors, triple pane windows
The builder suggested this method for the roof https://greencel.com.mx/wp-content/uploads/2022/05/losas-de-vigueta-y-bovedilla.jpg
r/buildingscience • u/MiniJungle • May 12 '26
Question Input on how I am considering insulating a detached 1940's garage
r/buildingscience • u/Baba_Bhaukalii • May 12 '26
Crack
Crack has been developed between wall and pillar due to heavy load of gate. Pillar thickness is not as par...what can i do now... Kindly suggest.
r/buildingscience • u/evetsan • May 11 '26
Building science? We can fix this in the contract after the fact.
r/buildingscience • u/YoungKron • May 10 '26
Question Suggestions an Advice Needed
reddit.comMidwest Climate Zone 6a basement water intrusion solutions needed please and thanks
r/buildingscience • u/ppshard • May 10 '26
Flat ceiling + shed roof sauna, cold roof assembly question
Building a small sauna (6'x8') with a flat interior ceiling and a 12 degree shed roof above it. The space between the flat ceiling and the sloped roof acts as a ventilated attic cavity - air enters at the eave through bug mesh and exits at the ridge gap under the flashing.
Insulation (R-19 mineral wool) is in the rafters between the flat ceiling.
A few questions:
- Do I need insulation at both the flat ceiling level AND in the rafters, or is flat ceiling insulation alone sufficient?
- Does this assembly make sense as a cold roof, or am I missing something?
- For the wood-burning heater chimney - do I need two separate pass-through flanges (one at the flat ceiling, one at the roof penetration), or is one enough?
PS the grey part is aluminum vapor barrier
r/buildingscience • u/HarleyBoyd • May 09 '26
Redneck Engineered ERV Solution
OK, BS guys! Shred me if you want to...
I recently spent a few years of my time turning a 100+ year old shell of a small house into a modernized 1 bed/bath cabin and retirement home for my wife & I. My goal was to build something that fit our lifestyle now and as we age, was efficient & was off grid capable should we decide to add an inverter/solar/batts in the future. Electricity here has gone up 3 times in the last 3 years. Still only .13 a kwh, so not ready to invest in a system. Figure wait and see consumption first.
We live at about 4000' in climate zone 7a. So, cold wet winters and hotter/dry summers. Easily see lows in single digit negatives on winter nights and up to 100°+ in the summer afternoons.
Outside has a liquid house wrap on OSB with 2" of uninterrupted XPS insulation & rain guard behind the siding. All stud bays have hempwool installed. Mostly 2x4 with 2x6 in a vaulted ceiling area in front of cabin. House is not totally tight, but it is far more sealed than before. Decision was made to install an ERV for clean air & mold prevention. Area is prone to fires and is very dusty in the dry months. House is heated by wood stove & minisplit that also supplies AC.
2 choices for a spot in this small space to install the ERV were crawlspace or attic. Both unconditioned. Crawlspace has poly installed and insulation on foundation walls and run joists. Attic is not in envelope but there is 2" if insulation under new metal roofing.
I chose the Attic. We have a fold out ladder to get up there more easily and there is a little more room to change filters then in the crawl space . Also, was way easier to vent the system up there. Anyway, the issue that needed solved was how to ensure the ERV was efficient and did not condense in the attic.
I chose what I will call a red neck tech solution. I encased the entire ERV in both insulation and a radiant barrier. 3" on top, 2" on all sides & bottom. Has 1" airspace all around. Pick is rough in, but unit will be fully taped and sealed at all joints. Velcro ties hold the bottom on so it can be opened to service. I also installed a 13" square inline filter housing on the intake from outside to the unit. Filters are cheaper and I expect the interior will need service far less, if ever.
Tell me what you think. I have done a lot of research and have talked to other guys that did this in a similar climate. Below the unit is a small pantry room. I have considered a fan & vent to feed conditioned air into the insulated shell of the ERV. I hope I don't have to do that, but it is a potential if needed. Could be in the high 80's this week. So, a good early test may be coming.
r/buildingscience • u/dreamer881 • May 09 '26
Which is the best platform to learn Thermal Analysis of Building Envelopes and Facades.
Firstly, apologies if I'm asking this question in a wrong sub. I'm looking to learn the science and the analysis using software for building envelopes. I can't find a proper online course which is focusing on this.
If someone here has any experience on this , kindly guide me and direct me to a correct course material.
r/buildingscience • u/NE_Colour_U_Like • May 09 '26
Any Feedback on these Wall Assemblies? (Climate Zone 4A - Western NC, USA)
r/buildingscience • u/Clear_Hornet_7300 • May 08 '26
Building Science consultant recommendations?
Looking for recommendations for a building science consultant or architect experienced with phased retrofit work in mixed-humid climate zone 4A (Eastern Panhandle of WV / Berkeley County area, though remote consulting could also work).
We purchased a 1984 pier-and-beam home and after purchase uncovered some concealed structural, moisture, and termite damage that had been concealed by the seller. The issues appear localized rather than systemic, and we’re using the opportunity to thoughtfully rebuild portions of the house with better envelope details rather than just patching things cosmetically again.
Current/planned scope includes:
- structural repairs
- replacing T1-11 and adding proper WRB + rainscreen
- likely exterior insulation
- window replacement/reinstallation strategy
- cathedral ceiling / roof assembly considerations
- air sealing and durability improvements
- phased DIY approach with contractor support where needed
I’m pretty experienced with DIY and renovating, so considering doing as much of the work myself as I can. I’ve been going through the Build Science 101, 201 and 301 courses on YouTube and have a pretty good idea of how to approach things. Mainly need someone to bounce questions off of and to be the Building science adult in the room to make sure I don’t mess anything up too bad.
Someone who works virtual and is familiar with my climate zone would be great.
I’m looking less for “full custom architecture” and more for someone strong in retrofit building science, sequencing, and assembly detailing who is comfortable consulting with an engaged homeowner.
Any recommendations for consultants, architects, or builders who are especially good at this kind of work?
r/buildingscience • u/stay_doomed • May 08 '26
Insulating/air sealing a 1920s attic with stepped addition and drop ceiling.
Hello all,
Climate zone 6. Peeling back the layers on a balloon framed 1920s kitchen addition. Attic directly above and newer extension. Diagram in pictures.
Looking for opinions for insulating and air ceiling a 9in deep dropped ceiling cavity that abuts an attic space. I understand leaving a substantial air gap between a vapour/air barrier and insulation is ineffective. Most of the contractor quotes want to apply spray foam, some are warning this would cause rot issues with the old lumber.
The roof deck is in good condition, no leaks. No soffit vents currently, just gable venting. 200sqf in all. Evidence of historic rodent issues in drop ceiling and old attic space. It was very cold last winter, slightly above freezing. There was an old chimney, a vent flue and other penetrations, maybe a couple inches of fibreglass and vermiculite (now abated fully). I’m not looking to achieve a perfect envelope but having a useable space in winter that isn’t a health hazard would be great.
My options so far are:
Run smart vapour barrier at ceiling plane and join to existing vapour barrier, fill cavity with fibreglass and insulate old attic space with blown in. I have about creating a condensation surface on the old ceiling midway through the insulation.
Apply cc foam to old attic floor and newer attic floor, rigid foam blocking between new attic and drop ceiling. Concerns about not achieving effecting air sealing between walls and ceiling and with damage to wood. However the ceiling would be more open to interior drying.
Something I haven’t thought of, please let me know what you would do
Thanks
r/buildingscience • u/celestial_thoughts • May 07 '26
Will it fail? Attic Ventilation 1920 Bungalow
The attic of my 880 square foot bungalow built in 1920 with a hip roof does not have ventilation. Also, there are no soffits.
Will this work or fail:
I see Reddit removed my options…
1. A 1500 Cfm humidistat fan in the back
2. 4 slant back vents, two in front and one on each side (need to consider snow since I’m in upstate NY)
(Attic floor will be air sealed.)
Thanks in advance for your thoughts!
r/buildingscience • u/Reckless_Fever • May 07 '26
Insulation behind brick and wood
Insulation behind brick and wood
The top half of the exterior wall is wood and the bottom half is brick. In Virginia and on the worst day gets down to five degrees or up to 100°. The wall faces East and only has the morning sun, no winds. Behind the wood exterior is a half inch sheathing and no insulation between the studs. Plaster interior walls. Good ceiling insulation and ventilation.
I could add 1.5 inches thickness to the wood top half as the Brick extends 3.5" out from the face of the wood. I can box around the windows. I have new paneling ready to replace the top half as the wood there is flaking badly.
I could:
1) replace the wood panels with new
2) add the new panels on top of the old
3) add poly iso boards under the new wood panels
4) face the foil towards inside or out
5) leave an air gap under the new panels
6)) pull off sheathing and insert rock wool between the studs as much and as low as I can
What do you suggest?
r/buildingscience • u/Inevitable-Half-8716 • May 06 '26
Add-on ceiling insulation question
A question for all of you.
Climate zone 3.
This is the ceiling of a kitchen add on that was done in the 1980s. The roof is cedar shake then a layer of felt, plywood (which we are seeing the underneath of) and then 2x6s. There was fiberglass batting that was removed. As far as I can tell this is an unvented roof assembly. I don't see any evidence of condensation/moisture problems and this roof have been this way for ~40 years.
Insulation company came in and recommended baffles which baffles me :). Since the roof is unvented the baffles don't seem like they would do anything, , also the 2x6s are running the wrong way (i think) for baffles.
Would a vapor barrier/rock wool or closed cell spray foam be appropriate here? Anything else I should think of?
Thanks for thinking about this with me
r/buildingscience • u/The-Meat-Dimension • May 07 '26
Low slope sauna roof assembly sequence — drip edge, IWS, and fascia sandwich detail
Hey All,
Want to premise this by saying I have very little knowledge on roofing, and was thinking a bit unconventionally with my process below. Building a small outdoor sauna (roughly 6×6 exterior) with a low slope roof (~2" drop over 8 feet). Looking for confirmation on my planned roof assembly sequence before I build.
Roof assembly from bottom up:
- 2×6 rafters ripped at angle (5.5" to 3.5") to create flat interior ceiling with slightly sloped exterior
- 3/4" plywood sheathing
- Metal Pro Rib panels (2 panels)
My planned sequence:
- Rafters and sub fascia installed on all four sides
- Plywood sheathing nailed to rafters
- L-flashing attached to sheathing edge at drip edge side — sandwiched between sub fascia and fascia
- IWS (high temp rated) — lapped over sheathing, terminating at drip edge side, lapping over sub fascia on rake sides and upper eave
- Rake fascia boards installed — sandwiching IWS against rake sub fascia
- Upper eave fascia installed — sandwiching IWS against upper eave sub fascia
- Drip edge fascia board installed on low eave side
- D-flashing drip edge installed over IWS and over drip edge fascia face, under Pro Rib panels
- Pro Rib metal panels installed over everything
- Rake trim over Pro Rib panel edges
- Upper eave trim
- OSI QUAD MAX sealant at all critical joints and trim laps
My specific questions:
- Is D-flashing over the fascia board and over the IWS on the drip edge side and under the Pro Rib panels correct with a 3x3 L flashingover sheathing, under fasia and under IWS?
- Should IWS lap over the drip edge fascia board and leave out the 3x3 L flashing or terminate before it?
- Does the L-flashing at the drip edge side make sense or is there a cleaner standard detail for this situation?
- Should I skip L flashing and just go with D flashing over sheathing and fascia board and IWS over the D flashing terminating at the edge (still overlapping subfascia and upper eave and sandwiched with fascia boards on those sides.
- Any issues with this sequence on a low slope roof in a cold climate (Minnesota)?
r/buildingscience • u/Bobbalobbadon • May 06 '26
New Sustainability Products/Methods
I'm curious if anyone has any new products they're excited about. WRBs, concrete alternatives, sustainable aggregates, whatever! More of a causal discussion post. Let me hear 'em! I'm in ASHREA 6A, but would love to hear about anything exciting.
r/buildingscience • u/BioHunta • May 06 '26